  • Low Oxygen Chamber - Temperature Controlled Chamber
    has worked with one of the world s leading filter manufacturers to develop a filter specifically tailored to suit this Hypoxystation Levels of atmospheric cleanliness inside the workstation exceeds the requirements of ISO 14644 Class 3 equivalent to Class 1 of the US Fed Std 209E Cleanroom Standards and exeeds the particle counts attained at rest without an operator of Grade A as set out in the GMP Guidelines We can provide test results confirming particulate levels inside the workstation Fitted with a fan that circulates the internal atmosphere continuously contributing to even temperature distribution and ensuring any internal particulate will be in motion Has a removable front as standard to facilitate the transfer of bulk samples or larger pieces of equipment for use in the workstation No special tools are required and there are no loose parts to store 50 larger than a H35 Hypoxystation the additional space inside the H45 allows you to marshall your experiments more efficiently and study your samples using various pieces of equipment inside the workstation environment With three entry ports one instant access port for transferring and retrieving samples quickly and efficiently no need to run an airlock cycle and two oval sleeved ports for comfortable working inside the cabinet Built in rapid airlock to ensure samples can be transferred into the workstation atmosphere as soon as possible only takes 60 seconds Colour touch screen control panel for ease of use and for visual display of parameters such as O 2 level CO 2 level temperature humidity and airlock cycle status Compact footprint with fully integrated gas control no bulky add on systems to find additional bench space for CO 2 Monitoring device fitted as standard to enable you to experiment using different concentrations of CO 2 Optional automatic humidification system provides a sterile source of humidity to prevent media evaporation during extended incubation Two point oxygen sensor calibration that takes only 6 minutes Easy calibration using the touchscreen control panel and you don t have to remove the oxygen sensor from the workstation and risk a build up of condensation which could in turn lead to inaccurate readings View Specifications Specifications Capacity Litres 439 Port Airlock Capacity Accommodates up to 44 x 96 well plates or 84 x T25 culture flasks Airlock Size 12 litres 223 x 190 mm d x h Porthole System 1 x Instant Access Port 2 Manual Oval Sleeved Ports Gas Supplies CO2 Air N2 Footswitch Wireless Auto Sleeve Gassing Option available Internal Mains Socket Option available Storage Trays Option available Spotlight Inspection Lamp Option available Single Sample Entry Option available Data Logging Option available Airlock Cycle Time seconds 60 Extra Cable Glands Option available Microscope Option available Please contact us for more information Automatic Dehumidifier Fitted as standard Automatic Humidifier Option available Removable Front Fitted as standard Trolley Option Available Dimensions w d h mm 1660 x 810 x 710 Weight lbs kg 386 175 CO2 Monitoring Fitted as standard Vacuum Take off Option available Temperature Range

    Original URL path: http://www.dwscientific.co.uk/whitley-h45-hepa-hypoxystation/ (2016-02-11)
    Open archived version from archive


  • Tissue Culture Incubator - Whitley H85
    footswitch to allow you to work gloved or bare handed Built in 30 litre airlock for transfer of bulk samples and equipment into the workstation environment Colour touch screen control panel for ease of use and for visual display of parameters such as O 2 level CO 2 level temperature humidity and airlock cycle status Available with fully automatic humidification system so you can add moisture AND maintain a sterile environment Fully integrated gas control avoids bulky add on systems and reduces the need for additional bench space This Tissue Culture Incubator is ideal for use in university laboratories hospitals cancer research facilities View Specifications Specifications Capacity Litres 295 Airlock Size 30 litres Accommodates up to 133 x 96 well plates or 252 x T25 culture flasks or 18 x T175 culture flasks Porthole System Manual Gas Supplies CO2 Air N2 Footswitch Wireless Auto Sleeve Gassing Option available Internal Mains Socket Option available Spotlight Inspection Lamp Not applicable Single Sample Entry Option available ANO2 Conditions Monitor Not applicable Refrigeration Option available Data Logging Option available Airlock Cycle Time seconds 300 Extra Cable Glands Option available Microscope Option available Automatic Dehumidifier Fitted as standard Automatic Humidifier Not applicable Removable Front Not Available Trolley Option Available Dimensions w d h mm 1570 760 840 Weight lbs kg 330 150 CO2 Monitoring Fitted as standard Vacuum Take off Option available Temperature Range C 5 C above ambient up to 45 C Touchscreen control Yes Options A02643 Anotox or Catalyst Sachet Cradle A02945 Spare Cable Gland A03125 Single Plate Entry System Letterbox A30225 Single Plate Entry System with long support tray for larger items A03325 Single Plate Entry System with folding tray A03957 Nitrogen Regulator A03959 CO2 Regulator A03960 Air Regulator A04040 Automatic Gas Changeover Unit A05006 Trolley for A H85 with Refrigeration Unit

    Original URL path: http://www.dwscientific.co.uk/whitleyh85-hypoxystation/ (2016-02-11)
    Open archived version from archive

  • Whitley VA500 Workstation
    ports The Whitley VA500 is commonly used in the study and isolation of microaerophilic organisms including Campylobacter spp Helicobacter pylori and other similarly fastidious organisms It is a modular microbiology culture system that operates on up to four different gases to create a specific atmosphere Accommodates up to 700 Petri dishes Designed to be modular the system can be purchased with or without an airlock transfer system The porthole system can be used for sample transfer Supplied with an automated humidity control system with no user maintenance necessary Allows bare hand working Dual intensity lighting A range of options and accessories are available to tailor the VA500 Workstation to your specific requirements View Specifications Specifications Capacity Petri Dishes 540 700 Port Airlock Capacity 20 plates per port 40 Porthole System Motorised Gas Supplies Up to 4 separate cylinders of H2 N2 CO2 N2 Air Footswitch Wireless Auto Sleeve Gassing Not applicable Internal Mains Socket Option available Spotlight Inspection Lamp Not applicable Single Sample Entry Option available ANO2 Conditions Monitor Not applicable Refrigeration Option available Data Logging Not applicable Extra Cable Glands Option available Microscope Option available Automatic Dehumidifier Fitted as standard Automatic Humidifier Not applicable Removable Front Not Available Trolley Option Available Dimensions w d h mm 1040 760 800 Weight lbs kg 242 110 Temperature Range C 5 C above ambient up to 45 C Touchscreen control No Options A00054 Hydrogen Anaerobic Gas Mixture Regulator Two stage A00056 Carbon Dioxide Regulator Two stage A00057 Nitrogen Regulator Two stage A01554 Air Regulator Two stage A02580 Microscope and Bracket Assembly A02617 Internal Power Socket A02711 Single Plate Entry System Letterbox A04040 Automatic Gas Changeover Unit A05002 Whitley 500 Workstation Trolley A05009 Refrigeration Unit Consumables A00069 Drylube Powder A00210 30 Plate Petri Dish Rack A00243 Pressure Relief Oil A01923 Foam Cleanser UK

    Original URL path: http://www.dwscientific.co.uk/whitley-va500/ (2016-02-11)
    Open archived version from archive


  • Whitley VA500 Workstation + Airlock
    is a modular microbiology culture system that operates on up to four different gases to create a specific atmosphere Accommodates up to 700 Petri dishes Designed to be modular the system can be purchased with or without an airlock transfer system The porthole system can be used for sample transfer Supplied with an automated humidity control system with no user maintenance necessary Allows bare hand working Dual intensity lighting A range of options and accessories are available to tailor the VA500 Workstation to your specific requirements View Specifications Specifications Capacity Petri Dishes 540 700 Port Airlock Capacity 20 plates per port 90 plates via airlock 130 Porthole System Motorised Gas Supplies Up to 4 separate cylinders of H2 N2 CO2 N2 Air Footswitch Wireless Auto Sleeve Gassing Not applicable Internal Mains Socket Option available Spotlight Inspection Lamp Not applicable Single Sample Entry Option available ANO2 Conditions Monitor Not applicable Refrigeration Option available Data Logging Not applicable Airlock Cycle Time seconds 300 Extra Cable Glands Option available Microscope Option available Automatic Dehumidifier Fitted as standard Automatic Humidifier Not applicable Removable Front Not Available Trolley Option Available Dimensions w d h mm 1570 760 840 Weight lbs kg 363 165 Temperature Range C 5 C above ambient up to 45 C Touchscreen control No Options A00006 Electronic Gas Leak Detector A00054 Hydrogen Anaerobic Gas Mixture Regulator Two stage A00056 Carbon Dioxide Regulator Two stage A00057 Nitrogen Regulator Two stage A01554 Air Regulator Two stage A02580 Microscope and Bracket Assembly A02617 Internal Power Socket A02711 Single Plate Entry System Letterbox A02780 20 Plate Adaptor Kit A02785 Mini Incubator A02945 Spare Cable Gland A04040 Automatic Gas Changeover Unit A05002 Whitley 500 Workstation Trolley A05006 Trolley Extension to Accommodate Whitley Workstation Airlock A05009 Refrigeration Unit A06128 Large Additional Cable Gland A07207 Whitley Petrifoto System L00040

    Original URL path: http://www.dwscientific.co.uk/whitley-va500-airlock/ (2016-02-11)
    Open archived version from archive

  • Whitley VA1000 Workstation
    chamber Accommodates up to 1400 Petri dishes Uses up to four gases nitrogen carbon dioxide air and a 10 hydrogen 90 nitrogen mix Portholes can be used as mini airlocks to transfer up to 80 x 90mm Petri dishes at the same time as an operator s arms are inserted or withdrawn from the workstation Supplied with an automated humidity control system with no user maintenance necessary Allows bare hand working Adjustable intensity lighting A range of options and accessories are available to tailor the modular and upgradeable VA1000 Workstation to your specific requirements View Specifications Specifications Capacity Petri Dishes 1080 1400 Port Airlock Capacity 20 plates per port 80 Porthole System Motorised Gas Supplies Up to 4 separate cylinders of H2 N2 CO2 N2 Air Footswitch Wireless Auto Sleeve Gassing Not applicable Internal Mains Socket Option available Spotlight Inspection Lamp Not applicable Single Sample Entry Option available ANO2 Conditions Monitor Not applicable Refrigeration Not applicable Data Logging Not applicable Extra Cable Glands Option available Microscope Option available Automatic Dehumidifier Fitted as standard Automatic Humidifier Not applicable Removable Front Not Available Trolley Option Available Dimensions w d h mm 1885 760 800 Weight lbs kg 407 185 Temperature Range C 5 C above ambient up to 45 C Touchscreen control No Options A00054 Hydrogen Anaerobic Gas Mixture Regulator Two stage A00056 Carbon Dioxide Regulator Two stage A00057 Nitrogen Regulator Two stage A01554 Air Regulator Two stage A02580 Microscope and Bracket Assembly A0261 7 Internal Power Socket A02711 Single Plate Entry System Letterbox A02780 20 Plate Adaptor Kit A02785 Mini Incubator A02945 Spare Cable Gland A04040 Automatic Gas Changeover Unit A05003 Whitley 1000 Workstation Trolley A05009 Refrigeration Unit A06128 Large Additional Cable Gland A07207 Whitley Petrifoto System L00040 Temperature Mapping Consumables A00069 Drylube Powder A00210 30 Plate Petri Dish Rack A00243

    Original URL path: http://www.dwscientific.co.uk/whitley-va1000/ (2016-02-11)
    Open archived version from archive

  • Whitley VA1000 Workstation + Airlock
    multiple samples or pieces of equipment in and out of the chamber Accommodates up to 1400 Petri dishes Uses up to four gases nitrogen carbon dioxide air and a 10 hydrogen 90 nitrogen mix Portholes can be used as mini airlocks to transfer up to 80 x 90mm Petri dishes at the same time as an operator s arms are inserted or withdrawn from the workstation Supplied with an automated humidity control system with no user maintenance necessary Allows bare hand working Adjustable intensity lighting A range of options and accessories are available to tailor the modular and upgradeable VA1000 Workstation to your specific requirements View Specifications Specifications Capacity Petri Dishes 1080 1400 Port Airlock Capacity 20 plates per port 90 plates via airlock 170 Porthole System Motorised Gas Supplies Up to 4 separate cylinders of H2 N2 CO2 N2 Air Footswitch Wireless Auto Sleeve Gassing Not applicable Internal Mains Socket Option available Spotlight Inspection Lamp Not applicable Single Sample Entry Option available ANO2 Conditions Monitor Not applicable Refrigeration Not applicable Data Logging Not applicable Airlock Cycle Time seconds 300 Extra Cable Glands Option available Microscope Option available Automatic Dehumidifier Fitted as standard Automatic Humidifier Not applicable Removable Front Not Available Trolley Option Available Dimensions w d h mm 2415 760 840 Weight lbs kg 528 240 Temperature Range C 5 C above ambient up to 45 C Touchscreen control No Options A00054 Hydrogen Anaerobic Gas Mixture Regulator Two stage A00056 Carbon Dioxide Regulator Two stage A00057 Nitrogen Regulator Two stage A01554 Air Regulator Two stage A02580 Microscope and Bracket Assembly A02617 Internal Power Socket A02711 Single Plate Entry System Letterbox A04040 Automatic Gas Changeover Unit A05003 Whitley 1000 Workstation Trolley A05006 Trolley Extension to Accommodate Whitley Workstation Airlock A05009 Refrigeration Unit Consumables A00069 Drylube Powder A00210 30 Plate Petri

    Original URL path: http://www.dwscientific.co.uk/whitley-va1000-airlock/ (2016-02-11)
    Open archived version from archive

  • Introduction to Clinical Anaerobic Bacteriology
    Sales History Products Services Overseas Distributors Exhibitions Equipment Rental Example Join the Team Workstation Poster Grant Corporate Literature Practical and Clinical Microbiology of Anaerobes Leeds University Microbiology Prize Posters Refurbished Equipment Secure Login Contact Us 44 0 1274 595728 sales dwscientific co uk Follow Don Whitley Scientific Home Products Whitley Anaerobic Workstations Introduction to Clinical Anaerobic Bacteriology Got A Question Request A Callback Overview Specifications Options Consumables Images Videos Downloads Introduction to Clinical Anaerobic Bacteriology An Introduction to Clinical Anaerobic Bacteriology is a guide to enable the reader to isolate and identify 12 commonly occurring clinically important anaerobic bacteria It contains 60 pages and is printed in two versions one is spiral bound on waterproof tear resistant synthetic paper to withstand regular use at the bench Bench edition Order Code A03815 and one on normal paper ideal for use in the laboratory library Library edition Order Code A08000 The publication is illustrated with stunningly detailed colour photographs and attractive reference tables Designed to fill a gap in the practical reference materials currently available to support clinical laboratory practice for microbiologists the publication was written by Professor Michael W D Wren MBE FIBMS former consultant Biomedical Scientist in the microbiology department University College Hospital and visiting Professor at The University of Westminster With a foreword by Professor Brian Duerden Emeritus Professor of Medical Microbiology at Cardiff University and input from Dr Don Whitley Chairman and founder of Don Whitley Scientific Limited considerable expert knowledge has been combined to make this the most up to date reference guide for the modern clinical laboratory Images were kindly supplied by the Anaerobe Reference Unit Cardiff When ordering your copy please specify Bench or Library edition View Specifications Specifications Dimensions w d h mm 210 6 297 Options There are no current accessories for this

    Original URL path: http://www.dwscientific.co.uk/introduction-to-clinical-anaerobic-bacteriology/ (2016-02-11)
    Open archived version from archive

  • Whitley Jar Gassing System
    Workstations Whitley Jar Gassing System Got A Question Request A Callback Overview Specifications Options Consumables Images Videos Downloads Testimonials Whitley Jar Gassing System With the Whitley Jar Gassing System you can create perfect conditions for growing anaerobes in jars in just 2 minutes for less than 18 pence and for microaerophiles in 15 seconds for less than 3 pence compared with about 1 60 for every gas generating kit used Reduces the cost of creating microaerobic conditions by 98 and for anaerobic conditions by 89 A full colour touch screen control panel allows you to monitor in real time that the criteria necessary for the creation of either anaerobic or microaerobic conditions has been met It is easy to use so no complicated operator training is required Incorporates PIN code protected user access levels for additional security The optional printer enables you to create a hard copy audit trail for accreditation purposes If you already have anaerobic jars that you wish to use you can order the adaptor kit which will enable you to connect most types of jar View Specifications Specifications Gas Supplies ANO2 Dimensions w d h mm 200 400 350 Weight lbs kg 35 16 Speed approx Anaerobic 2 mins microaerophilic 15 secs Touchscreen control Yes Options A04724 Printer A05072 Adaptor Kit for Whitley Jar Gassing System 10 Plate Polycarbonate Jar A05080 Adaptor Kit for Jars Fitted with Pre drilled Holes A05083 Gas Line Tee piece to Connect to Existing Gas Line Consumables A00007 48 Plate Petri Dish Rack A00010 Oxoid Low Temperature Catalyst Sachet A01923 Foam Cleanser UK Only A02534 10 Plate Petri Dish Rack A03486 Printer Paper for Whitley Jar Gassing System A05076 48 Plate Anaerobic Jar for Whitley Jar Gassing System A05077 10 Plate Polycarbonate Jar for Whitley Jar Gassing System A05075 9 Plate

    Original URL path: http://www.dwscientific.co.uk/whitley-jar-gassing-system/ (2016-02-11)