  • gamatronic UK - Utility Company – Case Study
    center the company decided to upgrade heir data is very important thus the data center supply must be protected by an advanced UPS system which can be upgraded when additional power is needed Due to the sensitivity of their data center equipment the UPS must be on line at all times even when a quick repair or maintenance is required Another big challenge was the limited space in the data center room Therefore the 4x50kVA conventional UPS were replaced by the Mega Power The solution Initial inspection was done to insure the UPS will fit into the limited space The Mega Power with its 25 kVA per module was just the right size for their requirement as well as the space limitations An extra benefit was the reduced noise level compared to the conventional pervious UPS Mega Power 125kVA kW to 500kVA kW The Mega Power is a state of the art modular redundant UPS System With a capacity to grow up to 500kVA with 25kW increments The product s unbelievable small footprint and high efficiency makes it one of the world s leading solutions in it s range The product is utilized in many Datacenter rooms hospitals institutions manufacturing industrial applications telecom datacenters as well as many other segments System Characteristics Highest efficiency rate of 96 Significant energy and cooling savings Maximum Availability and Minimal Downtime The Highest Power Density Smallest Footprint 25kVA kW 3U and saves space in data centers IT rooms and other critical hosted sites All connections and cables are internal Minimal access to the sides and rear of the unit is required FRONT access only Highest level of load availability Even if a module fails it will not influence the system operation and load availability The system will continue to work uninterrupted Flexible scalability Mega

    Original URL path: http://www.gamatronic.co.uk/Utility%2DCompany%2DCase%2DStudy.html (2016-02-09)
    Open archived version from archive


  • gamatronic UK - Longjiang Bank Corporation Case Study
    Read more Longjiang Bank Corporation Case Study Customer Profile Longjiang Bank based in Harbin China offers its clients varied financial transactions beginning from small and personal needs and up to corporate institutional and international ones Apart from its headquarters in Harbin the bank holds 13 branch offices in Qiqihar Daqing Mudanjiang Qitaihe Heihe Kiamusze Yichun Hegang Da Hinggan Ling Shuang Yashan Suihua and Jixi The Challenge Since the company s branches are spread out Longjiang Bank searched for a solution that was both easy to access and repair The bank wanted to ensure the solution would be capable of growth according to the Bank s natural needs In addition Longjiang Bank wanted the solution they choose to be trust worthy thus continue to work at all times supplying clean and safe power supply The solution Due to its easy access and hot swap feature allowing for rapid repairs the Power Modular UPS was chosen Power power systems of different power supply were installed in the bank s computer room since 2008 and have been growing ever since accompanying the Bank s needs The Power scalability modularity redundancy and easy maintenance are the reasons the Gamatronic products were chosen for Power Classic 10 100kVA Power Classic is an electrically and mechanically modular 10 100kVA UPS system uniquely designed to flexibly grow as power requirements grow The product can be easily upgraded on site through addition of plug and play 10kVA modules up to 100kVA the system is designed for hot swap Power offers the optimal combination of efficiency economy and usability boasting the industry lowest TCO Total Cost of Ownership and fastest ROI Return on Investment Power is a parallel redundant UPS The system comprises of 1 to 10 UPS or 1 5 modules of 10kVA each a system controller static

    Original URL path: http://www.gamatronic.co.uk/Longjiang%2DBank%2DCorporation%2DCase%2DStudy.html (2016-02-09)
    Open archived version from archive

  • gamatronic UK - Fabrinet Thailand Case Study
    processing biotechnology metrology material processing auto safety and medical devices are on the rise The Challenge While building a new FAB which would allow it to enlarge its production line Fabrinet requested a solution capable of ensuring a reliable stable continuous power supply and protection to its critical equipment while guaranteeing an uninterruptible production line at all times The solution searched for had to convert the frequency of the power from 50 Hz to 60 Hz the main supply in Thailand provides 50Hz while the Fabrinet production equipment operates at 60Hz frequency being an American made equipment as well The solution In order to answer customers needs Gamatronic provided the Mega Power modular parallel UPS solution offering A totally green input power Unity power factor of 96 and less than 5 THDI provided by the Mega Power minimizes the size of the input upstream generator transformer switch gears and feeding cables The modular parallel redundant structure of the Mega system 25kVA 25VA power modules provides the highest load availability uptime of output power It ensures that even if one module or more malfunction they isolate themselves from the rest of the functioning modules allowing the power protection system to operate with the maximum possible uptime Optimized sizing and scalability the structure of the Mega Power enables the user to upscale the power protection solution when new equipment is added to the production line At Fabrinet the Mega Power operates as both a UPS and a static frequency converter which converts the input power from 50 Hz into a stable independent high quality output power of 60 Hz Small Footprint Thanks to the hot swap feature of the Mega Power the downtime MTTR mean time to repair of the power protection system is reduced to a few minutes and Individual malfunction power modules can be replaced in a very short time without shutting the whole system down The high power density of the Mega solution per volume and per weight allowed for 4 systems of 300kVA scalable up to 500kVA be positioned in a small room Fabrinet Thailand Case study Mega Power 125kVA kW to 500kVA kW The Mega Power is a state of the art modular redundant UPS System With a capacity to grow up to 500kVA with 25kW increments The product s unbelievable small footprint and high efficiency makes it one of the world s leading solutions in it s range The product is utilized in many Datacenter rooms hospitals manufacturing industrial applications telecom Datacenters as well as many other segments System Characteristics Highest efficiency rate of 96 Significant energy and cooling savings Maximum Availability and Minimal Downtime The Highest Power Density Smallest Footprint 25kVA kW 3U and saves space in data centers IT rooms and other critical hosted sites All connections and cables are internal Minimal access to the sides and rear of the unit is required FRONT access only Highest level of load availability Even if a module fails it will not influence the system operation and

    Original URL path: http://www.gamatronic.co.uk/Fabrinet%2DThailand%2DCase%2DStudy.html (2016-02-09)
    Open archived version from archive


  • gamatronic UK - Telecommunication – Case Study
    Footprint Read more Telecommunication Case Study Customer Profile One of the biggest Telecommunication companies in the Philippines Has huge data recovery centers in various locations in the Philippines The company s main business is mobile phone operation Aside from basic services its mobile telephony offers SMS messaging international roaming capability and other value added services through GSM technology and fixed line services using an advanced digital network The Challenge The UPS power system upgrade of their data center included the replacement of their old conventional UPS 4x60kVA in parallel with a UPS that is reliable efficient easy to service and with a small foot print The customer requested a UPS that would supply the load 24 7 without downtime even during repair or scheduled maintenance The solution The company purchased 2 x 4 x 100 kVA Gamatronic Power Classic due to the following advantages Hot swapping technology allowing the modules replacement without turning the UPS to bypass mode during maintenance Horizontal and vertical redundancy While the old system provided horizontal redundancy alone Due to high efficiency and low heat dissipation electricity consumptions was reduced and the number of air conditioning units turned on was reduced as well The Power Classic UPS was chosen because each 10kVA module provides minimal initial investment and scalability options for the future Power Classic 10 100kVA Power Classic is an electrically and mechanically modular 10 100kVA UPS system uniquely designed to flexibly grow as power requirements grow The product can easily be upgraded on site through addition of plug and play 10kVA modules up to 100kVA the system is designed for hot swap Power offers the optimal combination of efficiency economy and usability boasting the industry s lowest TCO Total Cost of Ownership and fastest ROI Return on Investment Power is a parallel redundant UPS

    Original URL path: http://www.gamatronic.co.uk/Telecommunication%2DCase%2DStudy.html (2016-02-09)
    Open archived version from archive

  • gamatronic UK - Environment Canada – Case Study
    Three phase UPS UPS for computers Battery backup power supply Uninterruptible power supply systems Distributors Entry Home small office Medium large business Industrial application Military Special Applications Telecom Impact of Correct Balance between UPS Efficiency Resilience Selecting an appropriate UPS solution involves many quality based considerations including Carbon Footprint and resilience Here Shri Karve Senior Technical Consultant at GAMATRONIC UK LTD examines Read more Replace Old UPSs to Reduce OPEX Carbon Footprint Read more Environment Canada Case Study Customer Profile Environment Canada s business is protecting the environment conserving the country s natural heritage and providing weather and meteorological information to keep Canadians informed and safe Environment Canada is a diverse organization where programs services and people lead the way in implementing the Government of Canada s environmental agenda The Challenge The The requested installation site is the primary data Center of Atlantic Operations held critical by Environment Canada Requested features included Hot swap power modules No preparatory software Small foot print Local service and support The solution The solution included a N 1 redundant UPS solution with two RM60kVA UPS and two COMMON battery strings providing the level of redundancy and future expansion attributing further value to the customer s requests Power Rack Mount 10 50 100kVA Power Rack Mount UPS is a complete end to end 19 10 100kVA or 10 50kVA rack mount solution ideal for datacenters The product includes UPS MMBS maintenance bypass breakers fuses and an internal or external matching battery cabinet This is a 19 variant of the Power UPS Uninterruptible Power Supply which can be inserted in any standard 19 rack available in two configurations 50kVA 5 Power modules with a height of 22U and 100kVA 10 Power modules with a height of 32U Built for high density aesthetics as well as usability

    Original URL path: http://www.gamatronic.co.uk/Environment%2DCanada%2DCase%2DStudy.html (2016-02-09)
    Open archived version from archive

  • gamatronic UK - Eastern Health Care Canada – Case Study
    Entry Home small office Medium large business Industrial application Military Special Applications Telecom Impact of Correct Balance between UPS Efficiency Resilience Selecting an appropriate UPS solution involves many quality based considerations including Carbon Footprint and resilience Here Shri Karve Senior Technical Consultant at GAMATRONIC UK LTD examines Read more Replace Old UPSs to Reduce OPEX Carbon Footprint Read more Eastern Health Care Canada Case Study Eastern Health is the largest integrated health authority in Newfoundland and Labrador serving a regional population of more than 290 000 and offering the full continuum of health and community services including public health long term care community services hospital care and unique provincial programs and services The Challenge The installation site is a primary data center for Eastern Health Care Newfoundland critical for the operation of this vast organization Mandatory requirements set by the customer Hot swap power modules allowing for uninterruptable back up even during maintenance and care No preparatory software Low cost especially since competing with Powerware Liebert solutions Small foot print Local service and support The solution The site was installed with N 1 redundant UPS solution with two RM80kVA UPS and two Common battery strings The solution provided Eastern Health Care with competitive priced products offering a high level of redundancy and inherent scalability allowing for future expansion Power Rack Mount UPS 10 50 100kVA Power RM is a complete end to end 19 10 100kVA or 10 50kVA rack mount solution ideal for datacenters The product includes UPS MMBS maintenance bypass breakers fuses and an internal or external matching battery cabinet This is a 19 variant of the Power UPS Uninterruptible Power Supply which can be inserted in any standard 19 rack available in two configurations 50kVA 5 Power modules with a height of 22U and 100kVA 10 Power

    Original URL path: http://www.gamatronic.co.uk/Eastern%2DHealth%2DCare%2DCanada%2DCase%2DStudy.html (2016-02-09)
    Open archived version from archive

  • gamatronic UK - Football Stadiums – Case Study
    UPS Efficiency Resilience Selecting an appropriate UPS solution involves many quality based considerations including Carbon Footprint and resilience Here Shri Karve Senior Technical Consultant at GAMATRONIC UK LTD examines Read more Replace Old UPSs to Reduce OPEX Carbon Footprint Read more Football Stadiums Case Study Customer Profile The Liga Nacional de Fútbol Profesional National Professional Football League more commonly known as the Liga de Fútbol Profesional LFP is a national sports association responsible for administering the two professional football leagues in Spain the Primera and Segunda Division The organization was founded in 1984 LEP is comprised of 42 clubs grouped into two divisions the Liga BBVA 20 clubs and Liga Adelante 22 clubs In any given season a club plays against each of the others in the same division twice once at their home stadium and once at their opponent s This makes for a total of 38 games played each season in Liga BBVA and 42 in Liga Adelante The Challenge Over 40 football stadiums each require more than 4 hours of power back up during seasonal games Uninterruptable football games demand a constant stable flow of power to emergency systems CCTV Cameras Audio Systems and Monetary Systems including Access and Ticket sales The solution Power Classic 10 100kVA Power Classic is an electrically and mechanically modular 10 100kVA UPS system uniquely designed to flexibly grow as power requirements grow The product can be easily upgraded on site through addition of plug and play 10kVA modules up to 100kVA the system is designed for hot swap Power offers the optimal combination of efficiency economy and usability boasting the industry lowest TCO Total Cost of Ownership and fastest ROI Return on Investment Power is a parallel redundant UPS The system comprises of 1 to 10 UPS or 1 5 modules

    Original URL path: http://www.gamatronic.co.uk/Football%2DStadiums%2DCase%2DStudy.html (2016-02-09)
    Open archived version from archive

  • gamatronic UK - High-Speed Rail in China – Case Study
    Audio Systems and Monetary Systems including Access and Ticket sales The solution Power Classic 10 100kVA Power Classic is an electrically and mechanically modular 10 100kVA UPS system uniquely designed to flexibly grow as power requirements grow The product can be easily upgraded on site through addition of plug and play 10kVA modules up to 100kVA the system is designed for hot swap Power offers the optimal combination of efficiency economy and usability boasting the industry lowest TCO Total Cost of Ownership and fastest ROI Return on Investment Power is a parallel redundant UPS The system comprises of 1 to 10 UPS or 1 5 modules of 10kVA each a system controller static switch module and distribution block The battery bank is common to all the modules and can be built as one or more branches for battery redundancy The Power controller has an internal communication PCB which in conjunction with Gamatronic PSM software enables remote management of Customer Profile High speed rail refers to any commercial train service in China with an average speed of 200 km h 124 mph or higher China has the world s longest high speed rail HSR network BBC reported that by 2012 China was expected to have more high speed railway track than the rest of the world combined China s high speed rail network consists of upgraded conventional railways newly built high speed passenger designated lines PDLs and the world s first high speed commercial magnetic levitation maglev line China is the first and only country to have commercial train service on conventional rail lines that can reach 350 km h 217 mph Brief The information service platform program of ShiTai WenFu FuXia YongTaiWen ZhengXi and WuGuang altogether six passenger dedicated lines was approved to be built through State R D Commission The Service Platform of passenger dedicated lines include Ticket Systems Passenger Service Information Systems Office Automation Systems IC Card Management Systems Freight Management Systems and other information systems Among that WenFu Line includes 10 passenger stations 9 out of them deal with freight management system as well There can be 400 to 2 000 people gathered at the station therefore ensuring the whole service system operates smoothly and reliably running on stable power The Challenge The information platform of Railway Passenger Dedicated Line covers a wide range and a large area span The information system includes all aspects that are closely linked with passenger transport Therefore three points were requested for UPS system First the reliability of the system should be high enough to ensure the security of power supply and standard operation of information system Second along with the growth in business and load UPS should be easily scalable at last supplier should not only provide reliable products but also emergency service with quick fault solution The solution 8 sets of Power UPS systems 6 sets of Power 30kVA 1 set of Power 40kVA and 1 set of Power 50kVA have been first adopted in Fujian Section Program of