web-archive-uk.com


Web directory, archive
Search web-archive-uk.com:


Find domain in archive system:
web-archive-uk.com » UK » G » GAMATRONIC.CO.UK

Total: 143

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • gamatronic UK - Power + Reinforced 20kVA
    supply UPS Three phase UPS UPS for computers Battery backup power supply Uninterruptible power supply systems Distributors Entry Home small office Medium large business Industrial application Military Special Applications Telecom Impact of Correct Balance between UPS Efficiency Resilience Selecting an appropriate UPS solution involves many quality based considerations including Carbon Footprint and resilience Here Shri Karve Senior Technical Consultant at GAMATRONIC UK LTD examines Read more Replace Old UPSs to Reduce OPEX Carbon Footprint Read more Power Reinforced 20kVA This 19 inch 20kVA reinforced military UPS was developed specifically for the IDF to support its Iron Dome project The Iron Dome project intercepts and destroys short range rockets and artillery Additional features Military style connectors for AC input output and battery lines Stainless steel screws bolts and washers Circuit board solders comply with Class 3 standards Reinforcement of all structural and circuit board screws Critical components are strengthened with silicon rubber The system controller module includes an internal static switch The systems double conversion structure completely isolates the load connected to it from the mains utility The Power modules are hot swappable and light weight under 10kg The entire UPS fits into a standard 19 enclosure This reinforced UPS provides

    Original URL path: http://www.gamatronic.co.uk/Power%2DReinforced%2D20kVA.html (2016-02-09)
    Open archived version from archive


  • gamatronic UK - Semi-Military UPS – 3.6kVA–6kVA
    Impact of Correct Balance between UPS Efficiency Resilience Selecting an appropriate UPS solution involves many quality based considerations including Carbon Footprint and resilience Here Shri Karve Senior Technical Consultant at GAMATRONIC UK LTD examines Read more Replace Old UPSs to Reduce OPEX Carbon Footprint Read more Semi Military UPS 3 6kVA 6kVA Operation of this user friendly system requires no previous technical knowledge The UPS Uninterruptible Power Supply operates online providing 230V Online Double Conversion Semi Military Uninterruptible Power Supply 3 6kVA 6kVA at a stabilized frequency of 50Hz to any practical load During backup service the UPS Uninterruptible Power Supply is powered by batteries and maintains a constant output voltage supply LE indicators and audible signals inform the operator that a power failure has occurred The unit resides in three cabinets An electronics cabinet hosts all electronic devices charger inverter static switch microprocessor board panel etc 2 battery cabinets contain the batteries and circuit breaker Features Static switch that enables the powered devices to continue normal operation when the inverter is unable to supply exceptionally heavy loads such as during power surges or in case of inverter failure Front panel display provides complete real time information about the operational

    Original URL path: http://www.gamatronic.co.uk/Semi%2DMilitary%2DUPS%2D3%2D6kVA%2D6kVA%2D1.html (2016-02-09)
    Open archived version from archive

  • gamatronic UK - 19″ Military UPS 1.5kVA
    an appropriate UPS solution involves many quality based considerations including Carbon Footprint and resilience Here Shri Karve Senior Technical Consultant at GAMATRONIC UK LTD examines Read more Replace Old UPSs to Reduce OPEX Carbon Footprint Read more 19 Military UPS 1 5kVA A specially adapted model of the MP110 UPS for the IDF This military UPS unit complies with strict military standards including shock vibration and RFI standards and is suitable for military and naval applications for portable mobile and field based usage Military UPS Galvanic input to output isolationFeatures in addition to those of the MP110 UPS Full compatibility with compatible equipment EMC Operation as a noise filter Can work with a small 2kVA generator set Extra safety design with very rugged construction External emergency shutdown Back feed protection circuit prevents returning voltage from the inverter to the input terminals even when the unit fails This protects users and technicians from electicution RS232 serial connection for communication with an external PC Control and Monitoring Input voltage check Output load level check DC voltage battery check Temperature check Automatic and manual battery test Optional The Military UPS Systems can be fitted with a double casing for added protection In this

    Original URL path: http://www.gamatronic.co.uk/19%2DMilitary%2DUPS%2D1%2D5kVA%2D1.html (2016-02-09)
    Open archived version from archive


  • gamatronic UK - Marine Double-Conversion – 1-6kVA
    supply Ups 480v 3 phase UPS universal power supply UPS 80kva Telecom rectifier Uninterruptible power supplies UPS Uninterruptible power supply 30KVA Data center UPS Electric UPS Power supply UPS Three phase UPS UPS for computers Battery backup power supply Uninterruptible power supply systems Distributors Entry Home small office Medium large business Industrial application Military Special Applications Telecom Impact of Correct Balance between UPS Efficiency Resilience Selecting an appropriate UPS solution involves many quality based considerations including Carbon Footprint and resilience Here Shri Karve Senior Technical Consultant at GAMATRONIC UK LTD examines Read more Replace Old UPSs to Reduce OPEX Carbon Footprint Read more Marine Double Conversion 1 6kVA This non standard marine UPS system was designed for marine dynamic positioning and vessel control systems according to special engineering and mechanical requirements All system elements rectifier charger inverter STSW batteries are installed as independent modules in a closed and protected 19 16U cabinet with a front door Marine UPS Features Microprocessor control Selectable input voltage 110VAC to 250VAC Selectable input frequency from 45Hz to 65Hz Output THD 2 max Manual battery test Manual bypass switch static switch Bar graph and 5 LEDs for UPS Uninterruptible Power Supply status indications Alarm interface

    Original URL path: http://www.gamatronic.co.uk/Marine%2DDouble%2DConversion%2D1%2D6kVA.html (2016-02-09)
    Open archived version from archive

  • gamatronic UK - Medical µPS 3/3 10kVA
    supply 20KVA Uninterruptible power supply 500KVA Military UPS Systems Military uninterruptible power supply Ups 480v 3 phase UPS universal power supply UPS 80kva Telecom rectifier Uninterruptible power supplies UPS Uninterruptible power supply 30KVA Data center UPS Electric UPS Power supply UPS Three phase UPS UPS for computers Battery backup power supply Uninterruptible power supply systems Distributors Entry Home small office Medium large business Industrial application Military Special Applications Telecom Impact of Correct Balance between UPS Efficiency Resilience Selecting an appropriate UPS solution involves many quality based considerations including Carbon Footprint and resilience Here Shri Karve Senior Technical Consultant at GAMATRONIC UK LTD examines Read more Replace Old UPSs to Reduce OPEX Carbon Footprint Read more Medical µPS 3 3 10kVA PS 3 3 UPS 10kVA upgraded for medical applications PS 3 3 Medical Uninterruptible Power Supply 10kVA Gamatronics 10kVA 3 3 PS model was upgraded for medical applications allowing for full compliance with the Canadian standard cTUVus and the German standard TUV equivalent to the UL1778 standard To comply with these rigid standards the internal arrangement of the unit has been modified and its components have been redesigned Gamatronic Electronic Industries Ltd Uninterruptible Power Supply Power Supply Battery Backup Power

    Original URL path: http://www.gamatronic.co.uk/Medical%2DPS%2D3%2D3%2D10kVA%2D1.html (2016-02-09)
    Open archived version from archive

  • gamatronic UK - Parallel Naval UPS 3/3, 30kVA
    Ups 480v 3 phase UPS universal power supply UPS 80kva Telecom rectifier Uninterruptible power supplies UPS Uninterruptible power supply 30KVA Data center UPS Electric UPS Power supply UPS Three phase UPS UPS for computers Battery backup power supply Uninterruptible power supply systems Distributors Entry Home small office Medium large business Industrial application Military Special Applications Telecom Impact of Correct Balance between UPS Efficiency Resilience Selecting an appropriate UPS solution involves many quality based considerations including Carbon Footprint and resilience Here Shri Karve Senior Technical Consultant at GAMATRONIC UK LTD examines Read more Replace Old UPSs to Reduce OPEX Carbon Footprint Read more Parallel Naval UPS 3 3 30kVA These Parallel Naval frequency converters UPS systems 440Vac 60Hz to 115Vac 400Hz were designed especially for marine use The design is based on requirements of the Israeli Navy which tested and approved the units The frequency converters can be supplied in other capacities with or without batteries with standard and military compliance Features Input 3 440V 60Hz output 3 115V 60Hz or 400HZ Without STSSW B P With or without batteries Compliance with the following standards IEC 146 157 158 439 RFI EMI IEC 1800 3 NEPA 70 IEEE 18 1980 519

    Original URL path: http://www.gamatronic.co.uk/Parallel%2DNaval%2DUPS%2D3%2D3%2D30kVA%2D1.html (2016-02-09)
    Open archived version from archive

  • gamatronic UK - MBT, 20 kVA
    Correct Balance between UPS Efficiency Resilience Selecting an appropriate UPS solution involves many quality based considerations including Carbon Footprint and resilience Here Shri Karve Senior Technical Consultant at GAMATRONIC UK LTD examines Read more Replace Old UPSs to Reduce OPEX Carbon Footprint Read more MBT 20 kVA The MBT is a parallel redundant 20kVA UPS system The system is designed for military and naval applications therefore complies with strict standards and has a special strengthened 19 enclosure The UPS modules are designed for hot swapping The MBT UPS system is comprised of System Controller 1 to 3 UPS modules of 10kVA each Static Switch Module Features Reliability thanks to its N 1 parallel redundancy True on line battery design according to IEC62040 3 A green power solution thanks to THD of 5 at the input providing clean power to loads Employs active current sharing at the input output Has an overall e ciency of up to 96 and backup e ciency of 98 Light and small a 10 kVA module weighs only 9 Kg Enclosure The UPS system enclosure includes several anchoring hooks to ensure its stability For easy access to the system s rear cabling the UPS module and

    Original URL path: http://www.gamatronic.co.uk/MBT%2D20%2DkVA.html (2016-02-09)
    Open archived version from archive

  • gamatronic UK - Power Plus Premium 10-100 kVA UPS
    Data center UPS Electric UPS Power supply UPS Three phase UPS UPS for computers Battery backup power supply Uninterruptible power supply systems Distributors Entry Home small office Medium large business Industrial application Military Special Applications Telecom Impact of Correct Balance between UPS Efficiency Resilience Selecting an appropriate UPS solution involves many quality based considerations including Carbon Footprint and resilience Here Shri Karve Senior Technical Consultant at GAMATRONIC UK LTD examines Read more Replace Old UPSs to Reduce OPEX Carbon Footprint Read more Power Plus Premium 10 100 kVA UPS The New Power Premium is an innovative upgraded modular 10 100kVA UPS system uniquely designed to flexibly grow along with power requirement needs Technical improvements provide the customer extended power control via enhanced user interface and the same footprint with an increase of 25 in Power output 10kVA kW POWER MODULE Module output increased by 25 to 10kW Faster communication between the power modules and the controller Increased stability of current sharing between modules Lower internal dc working voltages ADVANCED STATIC SWITCH Faster recognition and reaction to power surges and spikes Improved communication between the static switch and the controller Faster transfer time between inverter and bypass modes Additional Circuit redundancy New latch mechanism on the power feed source ensures system stability in the rare event of a static switch fault STATE OF THE ART CONTROLLER 7 color touch screen Fast and intuitive navigation to data display and configuration screens Faster continuous monitoring by the controller of all the UPS components Larger system log with added details and information System log can be exported through Ethernet or USB connections Control of on off state of each module Sophisticated battery test Continuous dynamic estimation of remaining backup time in battery mode User interface with 7 languages and optional others Timed automatic shutdown

    Original URL path: http://www.gamatronic.co.uk/Power%2DPlus%2DPremium%2D10%2D100%2DkVA%2DUPS%2D1.html (2016-02-09)
    Open archived version from archive



  •  


web-archive-uk.com, 2017-12-16