  • Crouzet - 3 phase over/under voltage relay M3US
    products Panel Monitor Relays Download PDF Skriv ut bild CROUZET CONTROL Crouzet 3 phase over under voltage relay M3US Phase control of line voltage Wide range input voltage 17 5 mm cabinet with DIN rail LED indication Field of application Technical data Dimensions Connection Order number Control relay for monitoring 3 phase networks without neutral Adjustable switch at the front for adjustment of correct voltage in 3 phase networks The switch s position is not registered until the operating voltage is switched on If the switch position is changed during operation all LEDs LED indications begin to flash but the unit will continue to function normally with the voltage that was set at the most recent power connection Monitors under voltage between the phases that can be set between 2 and 20 of Un measurement voltage and over voltage that can be set between 2 and 20 of Un Time delay Tt prevents relay change over in the event of temporary disturbances and is adjustable between 0 3 30 s Green LED Un indicates supply voltage OK Yellow LED R indicates active relay output Over under voltage Skriv ut bild 1 Over voltage 2 Hysteresis 3 Under voltage 4 L1 L2 L3 5 Relay 6 Limit value with time delay for over under voltage Supply voltage 3x208 480 V AC 50 60 Hz 10 Power consumption 1 8 VA Adjustable measurement range Lower limit value Upper limit value 208 V 12 max lower limit depending on min voltage 183 V AC 220 V 17 max lower limit depending on min voltage 183 V AC 480 V 112 130 V AC 10 max upper limit depending on max voltage 528 V AC Hysteresis static 2 of Un Display accuracy 3 Time delay start up 500 ms Time delay Tt 0 3

    Original URL path: http://www.oem.co.uk/products/Panel/Monitor_Relays/Crouzet_-_3_phase_over_under_voltage_relay_M3US/1158709-515984.html (2016-04-25)
    Open archived version from archive


  • Crouzet - 3 phase, phase control HWUA
    Disconnectors Temperature Controllers Terminals Thyristor Controllers Timers Transducers Transformers Pressure Flow Machine Safety Motors products Panel Monitor Relays Download PDF Skriv ut bild CROUZET CONTROL Crouzet 3 phase phase control HWUA Triggers alarm upon incorrect phase sequence phase interruption asymmetry and over under voltage Adjustable line voltage Measures returned voltage to 70 35 mm cabinet with DIN rail Field of application Technical data Dimensions Connection Order number Control relay for phase monitoring with regeneration of voltage and asymmetry Adjustable switch at the front for adjustment of correct voltage in 3 phase networks Voltage switch s position is not registered until the operating voltage is switched on If the switch position is changed during operation all LEDs LED indications begin to flash but the unit will continue to function normally with the voltage that was set at the most recent power connection The LEDs return to normal function when the correct voltage is restored The relay monitors the correct phase sequence between the three phases or if any phase is lacking measured U Phase interruption phase sequence and asymmetry Over and under voltage Skriv ut bild Skriv ut bild 1 L1 1 Limit value over voltage 2 L2 2 Hysteresis 3 L3 3 Limit value under voltage 4 Limit value for asymmetry 4 L1 L2 L3 5 Hysteresis 5 Relay 6 Relay 6 Delay upon exceeding limit value Tt 7 Delay upon exceeding limit value Tt Supply voltage 3x220 480 V AC 50 60 Hz 10 Power consumption 2 9 VA Selection of rated voltage line 220 380 400 415 440 480 V Time delay upon exceeding the limit value Tt 0 1 10 sec Time delay alarm Time delay start up 500 ms Hysteresis 2 of Un static value Output relay Max breaking current 5 A 2 change over contacts

    Original URL path: http://www.oem.co.uk/products/Panel/Monitor_Relays/Crouzet_-_3_phase_phase_control_HWUA/1158709-515960.html (2016-04-25)
    Open archived version from archive

  • Crouzet - 3 phase, phase control MWA
    Network Meters Software Pushbuttons Pilot Lights Relays RS 485 Converters Signalling SMS module Solid State Relays Switch Disconnectors Temperature Controllers Terminals Thyristor Controllers Timers Transducers Transformers Pressure Flow Machine Safety Motors products Panel Monitor Relays Download PDF Skriv ut bild CROUZET CONTROL Crouzet 3 phase phase control MWA Triggers alarm upon incorrect phase sequence phase interruption and asymmetry Adjustable line voltage Measures returned voltage to 70 17 5 mm cabinet with DIN rail Field of application Technical data Dimensions Connection Order number Control relay for phase monitoring with regeneration of voltage and asymmetry Adjustable switch at the front for adjustment of correct voltage in 3 phase networks Voltage switch s position is not registered until the operating voltage is switched on If the switch position is changed during operation all LEDs LED indication begin to flash but the unit will continue to function normally with the voltage that was set at the most recent power connection The LEDs return to normal function when the correct voltage is restored The relay monitors the correct phase sequence between the three phases or if any phase is lacking measured U Phase interruption phase sequence and asymmetry Skriv ut bild 1 L1 2 L2 3 L3 4 Limit value for asymmetry 5 Hysteresis 6 Relay 7 Delay upon exceeding limit value Tt Supply voltage 3x208 480 V AC 50 60 Hz 10 Power consumption 1 8 VA Selection of rated voltage line 208 220 380 400 415 440 480 V Time delay upon exceeding the limit value Tt 0 1 10 sec Time delay alarm Time delay start up 500 ms Hysteresis 2 of Un static value Output relay Max breaking current 5 A Max breaking voltage 250 V AC Operating temperature 20 C to 50 C Weight 80 g Approval Skriv ut bild

    Original URL path: http://www.oem.co.uk/products/Panel/Monitor_Relays/Crouzet_-_3_phase_phase_control_MWA/1158709-515948.html (2016-04-25)
    Open archived version from archive


  • Crouzet - 3 phase, phase control MWG
    products Panel Monitor Relays Download PDF Skriv ut bild CROUZET CONTROL Crouzet 3 phase phase control MWG Triggers alarm when phase sequence or phase interruption faults occurs Adjustable line voltage Measures returned voltage to 70 17 5 mm cabinet with DIN rail Field of application Technical data Dimensions Connection Order number Control relay for phase monitoring with voltage regeneration returned voltage up to 70 of the measurement voltage Adjustable switch at the front for adjustment of correct voltage in 3 phase networks The switch s position is not registered until the operating voltage is switched on If the switch position is changed during operation all LEDs LED indication begin to flash but the unit will continue to function normally with the voltage that was set at the most recent power connection The relay monitors the correct phase sequence between the three phases or if any phase is lacking measured U Phase interruption and phase sequence Skriv ut bild 1 L1 2 L2 3 L3 4 Relay Supply voltage 3x208 480 V AC 50 60 Hz 10 Power consumption 1 8 VA Selection of rated voltage line 208 220 380 400 415 440 480 V Time delay start up 500 ms

    Original URL path: http://www.oem.co.uk/products/Panel/Monitor_Relays/Crouzet_-_3_phase_phase_control_MWG/1158709-515940.html (2016-04-25)
    Open archived version from archive

  • Crouzet - 3 phase, phase control MWS, MWS2
    bild Skriv ut bild CROUZET CONTROL Crouzet 3 phase phase control MWS MWS2 Triggers alarm upon incorrect phase sequence phase interruption Wide range input voltage from 3x208 480 V AC 17 5 mm cabinet with DIN rail LED indication Does not measure returned voltage Field of application Technical data Dimensions Connection Order number Control relay for 3 phase network that monitors the phase sequence for phases L1 L2 and L3 and checks whether one or more phases are lacking As long as the phase sequence and voltages are correct 183 V AC the output relay s is closed and the yellow LED LED indication is on If a phase sequence or phase interruption fault occurs the relay drops out and the LED turns off Does not measure returned voltage Phase interruption and phase sequence Skriv ut bild 1 Relay Supply voltage MWS 3x208 480 V AC 50 60 Hz 10 MWS2 3x208 440 V AC 50 60 Hz 10 Power consumption 1 8 VA Measurement range MWS 183 528 V AC MWS2 183 484 V AC Time delay start up 500 ms Time delay alarm 100 ms Output relay Max breaking current 5 A Max breaking voltage 250 V AC

    Original URL path: http://www.oem.co.uk/products/Panel/Monitor_Relays/Crouzet_-_3_phase_phase_control_MWS_MWS2/1158709-515936.html (2016-04-25)
    Open archived version from archive

  • Crouzet - 3 phase, phase control MWU
    PDF Skriv ut bild CROUZET CONTROL Crouzet 3 phase phase control MWU Triggers alarm upon incorrect phase sequence phase interruption and under voltage Adjustable line voltage Measures returned voltage to 98 17 5 mm cabinet with DIN rail Field of application Technical data Dimensions Connection Order number Control relay for phase monitoring with voltage regeneration returned voltage up to about 98 of the measurement voltage Adjustable switch at the front for adjustment of correct voltage in 3 phase networks The switch s position is not registered until the operating voltage is switched on If the switch position is changed during operation all LEDs LED indication begin to flash but the unit will continue to function normally with the voltage that was set at the most recent power connection The relay monitors the correct phase sequence between the three phases or whether any phase is lacking The under voltage function which is adjustable between 2 and 20 enables the returned voltage to be measured up to about 98 This means that if there is a line voltage of 400 V and the relay is set to 2 under voltage the relay will trigger an alarm the relay output drops out if the voltage drops below 392 V Green LED Un indicates supply voltage OK Yellow LED R indicates active relay output Phase interruption and phase sequence Under voltage Skriv ut bild Skriv ut bild 1 L1 1 Hysteresis 2 L2 2 Limit value under voltage 3 L3 3 Phases L1 L2 L3 4 Relay 4 Relay 5 Delay upon exceeding limit value Tt Supply voltage 3x208 480 V AC 50 60 Hz 10 Power consumption 1 8 VA Selection of rated voltage line 208 220 380 400 415 440 480 V Time delay upon exceeding the limit value Tt 0 1

    Original URL path: http://www.oem.co.uk/products/Panel/Monitor_Relays/Crouzet_-_3_phase_phase_control_MWU/1158709-515944.html (2016-04-25)
    Open archived version from archive

  • Crouzet - 3 phase, phase control MWUA
    Controllers Terminals Thyristor Controllers Timers Transducers Transformers Pressure Flow Machine Safety Motors products Panel Monitor Relays Download PDF Skriv ut bild CROUZET CONTROL Crouzet 3 phase phase control MWUA Triggers alarm upon incorrect phase sequence phase interruption asymmetry and over under voltage Adjustable line voltage Measures returned voltage to 70 17 5 mm cabinet with DIN rail Field of application Technical data Dimensions Connection Order number Control relay for phase monitoring with regeneration of voltage and asymmetry Adjustable switch at the front for adjustment of correct voltage in 3 phase networks Voltage switch s position is not registered until the operating voltage is switched on If the switch position is changed during operation all LEDs LED indications begin to flash but the unit will continue to function normally with the voltage that was set at the most recent power connection The LEDs return to normal function when the correct voltage is restored The relay monitors the correct phase sequence between the three phases or if any phase is lacking measured U Phase interruption phase sequence and asymmetry Over and under voltage with range control Skriv ut bild Skriv ut bild 1 L1 1 Limit value over voltage 2 L2 2 Hysteresis 3 L3 3 Limit value under voltage 4 Limit value for asymmetry 4 L1 L2 L3 5 Hysteresis 5 Relay 6 Relay 6 Delay upon exceeding limit value Tt 7 Delay upon exceeding limit value Tt Supply voltage 3x208 480 V AC 50 60 Hz 10 Power consumption 1 8 VA Selection of rated voltage line 208 220 380 400 415 440 480 V Time delay upon exceeding the limit value Tt 0 1 10 sec Time delay alarm Time delay start up 500 ms Hysteresis 2 of Un static value Output relay Max breaking current 5 A Max

    Original URL path: http://www.oem.co.uk/products/Panel/Monitor_Relays/Crouzet_-_3_phase_phase_control_MWUA/1158709-515954.html (2016-04-25)
    Open archived version from archive

  • C-Lynx control relays
    abnormal operating conditions Machinery can then be temporarily stopped and faults remedied before expensive failures occur An important factor in the manufacturing industry is minimising production stops and maximising operating time C Lynx can hard monitor and protect your installations All equipment benefits from having control relays that handle monitoring Conditions must be established for the equipment or machinery to perform the planned tasks on time 2 All deviations can be detected The control relay monitors and detects abnormal operating conditions of electrical or physical parameters voltage current phase level for all equipment even the most specialised goods lifts machines motors conveyors etc If a deviation is detected the control relay indicates this visually and conducts a contact change over at the relay output 3 Optimise operating time All equipment in the industry and service sectors benefits by letting control relays handle monitoring for optimising operating time This relay permits operators to plan service or repairs in ample time to avoid costly production stops Skriv ut bild Benefits of C Lynx control relay series Combination of several functions in the same enclosure makes wiring easier and facilitates commissioning The new module formats 17 5 mm and 35 mm cabinet with DIN rail make your equipment significantly less space demanding Measure true RMS even if the sinus curves are deformed The Easy to Use function LED indication provides information about production disturbances in your installation and about any mistakes made during installation and when making settings The new generation s integrated supply with wide range input voltage optimises the number of components and makes it easier to choose products Galvanic isolation between the operating and measuring sides are standard for the measuring relay series Environmental design The C Lynx control relay series has been developed entirely in accordance with the rules

    Original URL path: http://www.oem.co.uk/products/Panel/Monitor_Relays/C-Lynx_control_relays/1158709-469619.html (2016-04-25)