web-archive-uk.com


Web directory, archive
Search web-archive-uk.com:


Find domain in archive system:
web-archive-uk.com » UK » O » OEM.CO.UK

Total: 482

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • Compact Transformers
    reliable connections Supplied complete with voltage links Isolating and safety isolating Designed to meet the needs of users with specific VA ratings such as original equipment manufacturers The terminals are designed to provide easy and quick connections Conform to IEC EN 61558 2 4 for 48 V 115 V and 230 V and IEC EN 61558 2 6 for 12 V and 24 V secondary Products suitable for building into equipment conforming to EN 61131 2 EN 60204 1 and EN 60439 1 standards IP 2x or xxB up to 250 VA IK 04 Max ambient operating temperature 35 C without derating Protected against accidental contact with live parts up to 220 VA Insulation voltage Primary Secondary 4 470 V Primary Earth 2 240 V Secondary Earth 12 24 V 250 V 48 115 and 230 V 1780 V Interference disturbance filter included Single phase Safety isolating transformers Primary 230 400 V Secondary 12 24 V Order no Power In VA According to IEC EN Admissable Instantaneous power at cos φ 0 5 0428 40 40 52 0428 41 63 87 0428 42 100 150 0428 43 160 250 0428 44 250 420 0428 45 400 900 0428 47 630 1 700 Primary 230 400 V Secondary 24 V Order no Power In VA According to IEC EN Admissable Instantaneous power at cos φ 0 5 0428 55 40 VA 55 0428 56 63 VA 91 0428 57 100 VA 140 0428 58 160 VA 205 0428 59 220 VA 290 0428 60 310 VA 345 0428 61 450 VA 1 100 0428 62 630 VA 1 520 Safety isolating transformers Primary 230 400 V Secondary 24 48 V Order no Power In VA According to IEC EN Admissable Instantaneous power at cos φ 0 5 0428 70 40 VA

    Original URL path: http://www.oem.co.uk/products/Panel/Transformers/Compact_Transformers/2466470-1576468.html (2016-04-25)
    Open archived version from archive


  • Control, Signalling And Isolation Transformers
    DIN rail or mounting plate fixing Interference disturbance filter Integrated electrostatic shield General Information Technical data Order numbers Specifically designed to meet the needs of control and signalling isolation and safety isolation Legrand s open type single phase transformers are suited to a multitude of applications Ideal for heavy automation systems industrial process systems and complex machinery Primary tapping 15 V 40 VA to 4000 VA Permanent laser engraved markings DIN rail or mounting plate fixing Integral electrostatic shield Interference disturbance filter Visible terminals ensure safe and reliable connections Supplied complete with voltage links IP 2x or xxB up to 400 VA IP xxA above 400 VA IK 04 Conform to IEC EN 61558 2 2 and 2 4 or 2 6 UL506 and CSA C22 2 N 66 Products suitable for building into equipment conforming to EN 61131 2 EN 60204 1 and EN 60439 1 standards Insulated covers up to 1 000 VA provided Interference disturbance filter included Screw fix to mounting plate or clip on to DIN rail up to 250 VA Supplied with 0V Earth connection link up to 1 000 VA Single phase Primary 230 400 V 15 V Secondary 24 48 V Supplied with 2 links Order no Power In VA According to IEC CSA According to UL Admissable Instantaneous power at cos φ 0 5 0442 31 40 40 52 0442 32 63 63 87 0442 33 100 100 150 0442 34 160 140 250 0442 35 250 210 420 0442 36 400 300 900 0442 37 630 500 1 700 0442 38 1 000 700 2 000 0442 39 1 600 700 8 500 0442 40 2 500 1 400 3 300 Safety isolating transformers Primary 230 400 V 15 V Secondary 115 230 V Supplied with 2 links Order no Power

    Original URL path: http://www.oem.co.uk/products/Panel/Transformers/Control_Signalling_And_Isolation_Transformers/2466470-1576471.html (2016-04-25)
    Open archived version from archive

  • CP2 series 2108 event counter 24x48 mm
    State Relays Switch Disconnectors Temperature Controllers Terminals Thyristor Controllers Timers Transducers Transformers Pressure Flow Machine Safety Motors products Panel Counters Crouzet Download PDF Skriv ut bild CROUZET CONTROL CP2 series 2108 event counter 24x48 mm Contact DC counter 8 digit LCD display height 7 mm Reset electrically or from front panel Replaceable lithium battery life 8 years Technical data Measurements Switch Installation frames Order numbers Display 8 digits 7 mm Computing capacity 0 99 999 999 Inputs Low frequency In L Max 40 Hz T OFF 12 ms min T ON 12 ms min Contact or NPN open collector High frequency In H Max 7 kHz T OFF 70 μs min T ON 70 μs min Level 0 0 1 V DC Level 1 4 30 V DC Current consumption 6 mA max with 24 V DC Reset Contact Ok NPN open 12 ms min Front panel Ok General information Material ABS UL V0 self extinguishing IP class IP64 front panel Operating temperature 0 C 55 C Battery life 8 years lithium Weight 60 g Skriv ut bild Skriv ut bild Cutout 44 8x22 0 mm Poles 1 Reset 2 Front panel 3 Slow count 4 0 V 5 High

    Original URL path: http://www.oem.co.uk/products/Panel/Counters/Crouzet/CP2_series_2108_event_counter_24x48_mm/1158629-528135.html (2016-04-25)
    Open archived version from archive


  • CP2 series 2108H hour counter 24x48 mm
    Lights Relays RS 485 Converters Signalling SMS module Solid State Relays Switch Disconnectors Temperature Controllers Terminals Thyristor Controllers Timers Transducers Transformers Pressure Flow Machine Safety Motors products Panel Counters Crouzet Download PDF Skriv ut bild CROUZET CONTROL CP2 series 2108H hour counter 24x48 mm Contact DC counter 6 digit LCD display height 7 mm Reset electrically or from front panel Replaceable lithium battery life 5 years Technical data Measurements Switch Installation frames Order numbers Display 6 digits 7 mm Computing capacity 99 999 9 h 99 999 9 min 99 999 9 s 99 h 59 min 59 s Inputs Contact 1 start stop 40 ms min poles 3 5 Reset 100 ms min poles 1 3 Programming poles 3 4 Front panel reset allowed Reset Contact Ok NPN open 100 ms min Front panel Ok General information Material ABS UL V0 self extinguishing IP class IP64 front panel Operating temperature 0 C 55 C Battery life 5 years lithium Weight 60 g Skriv ut bild Skriv ut bild Cutout 44 8x22 0 mm Skriv ut bild Poles 1 Reset 2 Front panel reset allowed 3 Common 4 Programming 5 Start stop Skriv ut bild Start stop Programming Reset Area

    Original URL path: http://www.oem.co.uk/products/Panel/Counters/Crouzet/CP2_series_2108H_hour_counter_24x48_mm/1158629-528145.html (2016-04-25)
    Open archived version from archive

  • CP2 series 2214 hour counter 24x48 mm
    Relays Nano PLC Panel Meters Power Supplies Power Network Meters Software Pushbuttons Pilot Lights Relays RS 485 Converters Signalling SMS module Solid State Relays Switch Disconnectors Temperature Controllers Terminals Thyristor Controllers Timers Transducers Transformers Pressure Flow Machine Safety Motors products Panel Counters Crouzet Download PDF Skriv ut bild CROUZET CONTROL CP2 series 2214 hour counter 24x48 mm AC DC counter 6 digit LCD display height 7 mm 4 time ranges and current time setting selectable Replaceable lithium battery life 5 years Technical data Measurements Wiring Installation frames Order numbers Display 6 digits 7 mm Time range 99 999 9 h 99 999 9 min 99 h 59 min 59 s Input Voltage 5 50 V AC DC 48 240 V AC Frequency AC 10 Hz DC 14 Hz Reset Insulated from pulse input Front panel Can be switched off Electrical 5 50 V AC DC 8 240 V AC General information Insulation resistance 100 MΩ 500 V DC Material ABS UL V0 self extinguishing IP class IP66 front panel Battery life 5 years lithium Operating temperature 10 C 55 C Weight 65 g Skriv ut bild Perforation 22 0x44 8 mm Skriv ut bild Frame 25x50 mm Frame 45x45 mm

    Original URL path: http://www.oem.co.uk/products/Panel/Counters/Crouzet/CP2_series_2214_hour_counter_24x48_mm/1158629-528149.html (2016-04-25)
    Open archived version from archive

  • CP2 series 2293/2294 total event counter 24x48 mm
    Lights Relays RS 485 Converters Signalling SMS module Solid State Relays Switch Disconnectors Temperature Controllers Terminals Thyristor Controllers Timers Transducers Transformers Pressure Flow Machine Safety Motors products Panel Counters Crouzet Download PDF Skriv ut bild CROUZET CONTROL CP2 series 2293 2294 total event counter 24x48 mm AC DC counter 6 digit LCD display height 7 mm Replaceable lithium battery life 5 years IP class of front panel IP66 Technical data Measurements Wiring Installation frames Order numbers Display 6 8 digits 7 mm Computing capacity Sum 0 999 999 P on display Grand total 0 99 999 999 Inputs 2293 2294 Low frequency 14 Hz min pulse time 35 ms Contact Voltage High frequency 100 Hz min pulse time 5 ms Contact Reset insulated against counter input Front panel resets event counter Electrical resets event counter and grand total Contact Voltage 5 50 V AC DC 48 240 V AC General information Insulation resistance 100 MΩ 500 V DC Material ABS UL V0 self extinguishing IP class IP66 front panel Operating temperature 10 C 55 C Battery life 5 years lithium Weight 60 g 2293 65 g 2294 Skriv ut bild Perforation 22x44 8 mm Skriv ut bild Frame 25x50 mm

    Original URL path: http://www.oem.co.uk/products/Panel/Counters/Crouzet/CP2_series_2293_2294_total_event_counter_24x48_mm/1158629-528137.html (2016-04-25)
    Open archived version from archive

  • CPT4 series preselecting counter 48x48mm
    Download PDF Skriv ut bild CROUZET CONTROL CPT4 series preselecting counter 48x48mm Pulse counter batch batch counter tachometer time counter One or two presets Adjustable output 20 ms 1 s 6 digit LCD or LED display Technical data Measurements Switch Mode selection Order numbers Display LED Red 6 digits height 7 6 mm LCD Green 6 digits height 9 mm Supply voltage 12 24 V DC 10 24 V AC 10 115 V AC 10 230 V AC 10 Adjustment factor Adjustable 0 001 999 999 Memory In a power outage EEPROM remembers counter s value and program Inputs Countup countdown counter direction cumulatuve count pulse sensor phase PNP and NPN logic Reset Counting from zero 0 to preset Counting from preset P to zero Automatic or manual from voltage or front panel Outputs Pole exchange relay Semiconductor output Max load 5 A 30 mA Max voltage 30 V DC 250 V AC DC model 24 V DC AC model 30 V DC General information Switch Screw terminal IP class IP65 front panel Operating temperature 0 C 50 C Weight DC model 100 g AC model 200 g Approvals CE Rohs UL cULus Skriv ut bild Skriv ut bild 1 Panel thickness 1 10 mm Aperture 45 x 45 mm Panel adapter Skriv ut bild AC model 2 presets DC model 2 presets 1 AC supply voltage 1 Switched off 2 Semiconductor output 2 2 Semiconductor output 2 3 Relay output 2 3 Relay output 2 4 Probe power supply 4 DC output 5 0 V 5 0 V 6 Counter or control output 6 Counter or control output 7 Semiconductor output 1 7 Semiconductor output 1 8 Relay output 1 8 Relay output 1 Note Terminal 1 can be connected to outputs A B or C by a switch

    Original URL path: http://www.oem.co.uk/products/Panel/Counters/Crouzet/CPT4_series_preselecting_counter_48x48mm/1158629-528174.html (2016-04-25)
    Open archived version from archive

  • Crouzet - Single phase for separate heat sink, 10-100 A AC
    Amp states the current load current A solid state relay generates more heat than e g a contactor i e the indoor temperature in the curve must include the temperature increase added to the cabinet when the relay is operational Series GN is available in contact protection and non contact protection versions as illustrated here The contact protection design is the model primarily held in stock and has the greatest advantages The cover can be removed for easier connection Input data DC controlled AC DC controlled Supply voltage 4 32 V DC 90 280 V AC DC Release voltage 1 V 10 V Internal consumption 14 mA 8 5 mA Operate time ms 10 mA 20 mA Release time ms 10 mA 30 mA Output data Load current see diagram for load reduction 10 A 25 A 50 A 75 A 100 A Load voltage 24 280 V AC 24 280 V AC 48 660 V AC 48 660 V AC 48 660 V AC Voltage drop Imax 1 4 V 1 4 V 1 35 V 1 3 V 1 3 V Leakage current mA 2 5 4 25 2 5 4 25 2 75 4 75 2 75 4 75 2 75 4 75 Overcurrent 1 sA 300 500 780 1000 1200 Peak voltage V 600 600 1200 1200 1200 Holding current mA 100 100 100 100 100 Heat resistance C W 0 4 0 4 0 25 0 155 0 155 I2t A2S 375 450 1041 1250 2535 3042 4166 5000 6000 7000 Zero voltage switching Yes Yes Yes Yes Yes Semiconductor Thyristor Thyristor Thyristor Thyristor Thyristor General data Ambient temperature 20 C to 80 C Isolation inputs outputs 4 kV Approvals CE marked UL CUL EMC compatible Weight 114 g Protection class IP20 Skriv ut bild Skriv ut bild Temperature curves for series GN GN10A GN25A GN50A Skriv ut bild Skriv ut bild Skriv ut bild GN75A GN100A GN125A Skriv ut bild Skriv ut bild Skriv ut bild Heat sink 2 C W Heat sink 0 7 C W Heat sink 0 6 C W Skriv ut bild Skriv ut bild Skriv ut bild 26532760 26532762 26532790 Heat sink 1 3 C W DIN rail adapter Thermal foil Skriv ut bild Skriv ut bild Skriv ut bild HR1 AX2 DL01 26532720 The dimensions in the diagrams are with solid state relays GN mounted and with the height of the DIN rail included DIN rail adapter ordered separately Order no Description Load current Supply voltage Load voltage 84137000 Solid state relay 1 phase GN 10 A 24 280 V 4 32 V DC 10 A AC 4 32 V DC 24 280 V AC 84137001 Solid state relay 1 phase GN 10 A 24 280 V 90 280 V AC DC 10 A AC 90 280 V AC DC 24 280 V AC 84137010 Solid state relay 1 phase GN 25 A 24 280 V 4 32 V DC 25 A AC 4 32 V DC 24

    Original URL path: http://www.oem.co.uk/products/Panel/Solid_State_Relays/Crouzet/Crouzet_-_Single_phase_for_separate_heat_sink_10-100_A_AC/1158933-303466.html (2016-04-25)
    Open archived version from archive



  •  


web-archive-uk.com, 2017-12-12