  • Crouzet - Single phase for standard encapsulation 5 A AC
    Power Supplies Power Network Meters Software Pushbuttons Pilot Lights Relays RS 485 Converters Signalling SMS module Solid State Relays Crouzet Crydom Delcon Switch Disconnectors Temperature Controllers Terminals Thyristor Controllers Timers Transducers Transformers Pressure Flow Machine Safety Motors products Panel Solid State Relays Crouzet Download PDF Skriv ut bild CRYDOM Crouzet Single phase for standard encapsulation 5 A AC Load current 5 A AC Suitable in standard encapsulation Integrated semiconductor fuse Activated in zero voltage switching Area of use Technical data Dimensions Connection Order number GMS5 is a solid state relay in a standard enclosure for loads up to 5 A It features integrated semiconductor fuse and LED indication on the control input A varistor should be mounted on the load output connection 1 2 as solid state relays are sensitive to high transients on the mains The diagram for the load reduction are used to optimally dimension the size of the relay The temperature defines the cabinet s inside temperature Amp states the current load current Remember a solid state relay generates more heat than e g a contactor i e the temperature in the curve must include the temperature increase added to the cabinet when the relay is operational Load reduction Skriv ut bild Input data Supply voltage 4 32 V DC Internal consumption 10 22 mA Operate time max 10 ms Release time max 10 ms Output data Load current 5 A AC1 Load voltage 12 280 V AC 47 63 Hz Load reduction at C 30 C ambient temperature Voltage drop 1 6 V Leakage current max 2 mA Min current 50 mA Peak current one cycle 100 A Peak voltage t 1 min 600 V Semiconductor Triac Semiconductor fuse Integrated General data Ambient temperature 30 C to 80 C Isolation inputs outputs 4 kV Approvals CE

    Original URL path: http://www.oem.co.uk/products/Panel/Solid_State_Relays/Crouzet/Crouzet_-_Single_phase_for_standard_encapsulation_5_A_AC/1158933-303480.html (2016-04-25)
    Open archived version from archive


  • Crouzet - Single phase with heat sink, 10-30 A AC
    max 20 mA 10 A 10 mA 6 mA 8 mA Min operate current 16 mA 10 A 8 mA 5 mA 6 mA Reaction time on operation zero voltage switching 10 ms 20 ms 20 ms Response time on release 10 ms 30 ms 30 ms Output data Load current see diagram for load reduction 10 A 20 A 30 A Load voltage 24 280 V AC 48 600 V AC 48 600 V AC Peak voltage non repeating Vp 550 V AC 1100 V AC 1100 V AC Max leakage current at Vmax T 25 C 14 µAeff per phase 120 µAeff per phase 120 µAeff per phase Voltage drop across semiconductor at Imax 1 2 Vpeak 1 2 Vpeak 1 2 Vpeak I²t t 10 ms 340 A²s 1225 A²s 2850 A²s Peak current 1s T 25 C 30 A 100 A 150 A Semiconductor Triac Thyristor Thyristor General data Operating temperature 20 C to 80 C see load reduction Isolation inputs outputs earth 2500 Veff Weight 200 g Approvals IEC 62314 IEC60947 4 3 AC 51 CE in accordance with LVD 72 23 EEC UL cUL recognised by UL 508 CSA recognised by C22 2 no 14 95 TUV certified by EN 60950 Load reduction Load reduction current threshold failure level at raised temperature Diagram GNR 10 A Diagram GNR 10 A Diagram GNR 20 A Supply voltage 4 32 V DC and 90 140 V AC DC Supply voltage 180 280 V AC DC Supply voltage 4 32 V DC and 90 140 V AC DC Skriv ut bild Skriv ut bild Skriv ut bild Diagram GNR 20 A Diagram GNR 30 A Diagram GNR 30 A Supply voltage 180 280 V AC DC Supply voltage 4 32 V DC and 90 140 V AC

    Original URL path: http://www.oem.co.uk/products/Panel/Solid_State_Relays/Crouzet/Crouzet_-_Single_phase_with_heat_sink_10-30_A_AC/1158933-303570.html (2016-04-25)
    Open archived version from archive

  • Crouzet - Single phase with heat sink, 35-45 A AC
    led off quicker The relay is completely free of epoxy eliminates the risk of carbonization during abnormal heating Connections and conductors on electronics are adapted so that they are permitted to move e g during temperature changes The relays feature LED indication on the control input integrated transient protection on the load output and RC protection on the input and output Input data Supply voltage 4 32 V DC 90 140 V AC 180 280 V AC Release voltage 1 V 10 V 10 V Internal consumption max 16 20 mA 6 mA 8 mA Operate time 10 ms 20 ms 20 ms Release time 10 ms 30 ms 30 ms Output data Load current see diagram for load reduction 35 A 45 A Load voltage 48 600 48 600 Frequency 47 63 Hz 47 63 Hz Peak voltage non repeating 1100 Vp 1100 Vp Max leakage current at Vmax T 25 C 120 µAeff per phase 120 µAeff per phase Voltage drop across semiconductor at Imax 1 35 Vpeak 1 35 Vpeak I²t t 10 ms 3000 A²s 3200 A²s Peak current 1s T 25 C 150 A 160 A Semiconductor Thyristor Thyristor General data Operating temperature 20 C to 80 C Isolation inputs outputs earth 4000 Vout Weight 400 g Approvals IEC 62314 IEC60947 4 3 AC 51 IEC60947 4 2 AC 53a CE in accordance with LVD 72 23 EEC UL cUL recognised by UL 508 CSA recognised by C22 2 no 14 95 TUV certified by EN 60950 GNR 45 mm Contactor Skriv ut bild Contactor Load connections are to the left control connections to the right of the relay GNR 45 mm Relay normally not stocked Skriv ut bild Relay Load connections are on the lower edge and control connections on the top edge of

    Original URL path: http://www.oem.co.uk/products/Panel/Solid_State_Relays/Crouzet/Crouzet_-_Single_phase_with_heat_sink_35-45_A_AC/1158933-303575.html (2016-04-25)
    Open archived version from archive


  • Crouzet - Three phase with heat sink, 25 A AC
    AC Integrated heat sink Low voltage drop 1 2 V LED indication Area of use Technical data Dimensions Connection Order number Solid state relays are used to connect electrical loads with high currents and component parts must withstand being heated significantly The GNR series is based on new technology which means among others The voltage drop across the semiconductor is lowered to 1 2 V the relay generates less heat that must be lead off from the cabinet The semiconductor is located centrally on the heat sink the heat is distributed better and is led off quicker The relay is completely free of epoxy eliminates the risk of carbonization during abnormal heating Connections and conductors on electronics are adapted so that they are permitted to move e g during temperature changes The relays feature LED indication on the control input integrated transient protection on the load output and RC protection on the input and output Input data Supply voltage 4 32 V DC 90 140 V AC 180 280 V AC Release voltage 1 V 10 V 10 V Internal consumption max 22 30 mA 19 mA 24 mA Operate time 10 ms 20 ms 20 ms Release time 10 ms 30 ms 30 ms Output data 3x25 A Load voltage 48 600 V AC Frequency 47 63 Hz Peak voltage non repeating 1100 Vp Max leakage current at Vmax T 25 C 120 µAeff per phase Voltage drop across semiconductor at Imax 1 2 Vpeak I²t t 10 ms 1250 A²s Peak current 1s T 25 C 100 A Semiconductor Thyristor General data Operating temperature 20 C to 80 C see curve for load reduction Isolation inputs outputs earth 4000 Vout Weight 600 g Approvals IEC 62314 IEC60947 4 3 AC 51 IEC60947 4 2 AC 53a CE in

    Original URL path: http://www.oem.co.uk/products/Panel/Solid_State_Relays/Crouzet/Crouzet_-_Three_phase_with_heat_sink_25_A_AC/1158933-303578.html (2016-04-25)
    Open archived version from archive

  • Kuebler - Codix 529, 24x48 mm
    digits 8 mm high Scalable 19 999 to 99 999 Galvanic isolation Area of use Technical data Dimensions Connection Order number Universal instrument that measures 4 20 mA 0 20 mA 0 10 V or 2 10 V Display and measurement range programmed with buttons in an easy to understand menu system This facilitates commissioning as the required measurement signal is programmed in exactly followed by the required display value The settings are saved in EEPROM 10 years i e there is no battery in the instrument that needs to be changed The display can show the actual value lowest value and highest value selected with the right hand button can be reset The instrument features a latch function if input 4 is connected to a high control signal the display value freezes on the actual value The instrument can be used to display e g temperature pressure flow distance speed weight filling level acceleration etc An assembly bracket bezel for the panel cut out 25x50 mm bezel for the panel cut out 25x50 mm with screw holes seal self adhesive labels for different units and a manual English German French are supplied with the instrument Supply voltage 10 30 V DC galvanic isolated polarity protected Power consumption Max 50 mA Measurement range Current 0 20 mA 4 20 mA voltage drop max 2 V Voltage 0 10 V input imp 1 MΩ max input signal 30 V Control signals High signal 4 30 V DC Display latch Low signal 0 2 V DC Memory 10 years or 1 million memory cycles EEPROM Display 5 digits red 8 mm high Display resolution From 0 to 0 0000 Resolution 14 bits Linearity Accuracy Temperature operation Degree of protection IP65 at front Operating temperature 10 C to 50 C Storage temperature 25

    Original URL path: http://www.oem.co.uk/products/Panel/Counters/Kuebler/Kuebler_-_Codix_529_24x48_mm/1158636-303529.html (2016-04-25)
    Open archived version from archive

  • Kuebler - Instrument Codix 533, 24x48 mm
    Supplies Power Network Meters Software Pushbuttons Pilot Lights Relays RS 485 Converters Signalling SMS module Solid State Relays Switch Disconnectors Temperature Controllers Terminals Thyristor Controllers Timers Transducers Transformers Pressure Flow Machine Safety Motors products Panel Counters Kuebler Download PDF Skriv ut bild KÜBLER Kuebler Instrument Codix 533 24x48 mm Signal generator 4 20 mA 0 10 V Four digits 8 mm high Scalable 19 999 to 99 999 Time Ramping or manual General information Technical data Dimensions Connection Order number Codix 533 is a signal generator that produces an analogue current or voltage signal to an external set point or control signal for another device for example a digital potentiometer for speed control on a frequency converter etc Codix 533 has three basic functions manual direct control potentiometer manual ramping value jumps to preprogrammed step automatic ramping time control up to 20 values from 0 1 sec to 999 9 min Supply voltage 10 30 V DC galvanic isolated polarity protected Power consumption Max 50 mA Output signal Current 0 24 mA 4 24 mA Voltage 0 12 V 2kΩ res 10 mV Scaling 19 999 to 99 999 Control signals High signal 4 30 V DC Display hold Low signal 0 2 V DC Memory 10 years or 1 million memory cycles EEPROM Display 4 digits red 8 mm high Display resolution From 0 to 0 000 Protection class IP65 at front Operating temperature 20 C to 65 C Storage temperature 25 C to 85 C Weight 50 g Enclosure Dark grey RAL 7021 Connection Screw connection CE EMC In accordance with EU s EMC directive 89 36 EEC EN50 081 2 EN55 011 class B EN 6100 6 2 Skriv ut bild 1 10 30 V DC Skriv ut bild 2 0 V GND 3 0 V GND

    Original URL path: http://www.oem.co.uk/products/Panel/Counters/Kuebler/Kuebler_-_Instrument_Codix_533_24x48_mm/1158636-479225.html (2016-04-25)
    Open archived version from archive

  • Kuebler - Codix 531/532, 24x48mm
    for PT100 2 3 and 4 wire connection and Ni100 Codix 532 Temperature instrument for thermocouples type J K and N external or internal compensation for cold junction Display and sensor type programmed with buttons in an easy to understand menu system Compensation for cable resistance can be programmed max 20 ohm The settings are saved in EEPROM 10 years i e there is no battery in the instrument that needs to be changed The display can show the actual value lowest value and highest value selected with the right hand button can be reset The instrument features a latch function if input 4 is connected to a high control signal the display value freezes on the actual value The display also shows sensor failure Err 4 An assembly bracket bezel for the panel cut out 25x50 mm bezel for the panel cut out 25x50 mm with screw holes seal self adhesive labels for different units and a manual English German French are supplied with the instrument Supply voltage 10 30 V DC galvanic isolated polarity protected Power consumption Max 40 mA Temperature range PT100 199 9 C to 850 0 C 2 3 and 4 wire connection Ni100 60 0 C to 250 0 C Type J 210 0 C to 1200 0 C Iron constantan Fe CuNi Type K 200 0 C to 1372 0 C NiCr NiAl Type N 200 0 C to 1300 0 C NiCrSi NiSi Control signals High signal 4 30 V DC Display latch Low signal 0 2 V DC Memory 10 years or 1 million memory cycles EEPROM Display 5 digits red 8 mm high Display resolution 0 1 or 1 C F Linearity PT100 Thermocouple Temperature operation Degree of protection IP65 at front Operating temperature 20 C to 65 C relative

    Original URL path: http://www.oem.co.uk/products/Panel/Counters/Kuebler/Kuebler_-_Codix_531_532_24x48mm/1158636-303535.html (2016-04-25)
    Open archived version from archive

  • Kuebler - Codix 550, 48x96 mm
    buttons in an easy to understand menu system This facilitates commissioning as the required measurement signal is programmed in exactly followed by the required display value The settings are saved in EEPROM 10 years i e there is no battery in the instrument that needs to be changed This instrument also has a 24 point linearisation function e g to compensate measurement values for an asymmetrical shaped tank Display The display can show the actual value lowest value and highest value selected with the right hand button can be reset The instrument features a latch function if input 4 is connected to a high control signal the display value freezes on the actual value Communication Codix 55x series is available with serial interfaces for RS232 RS485 and RS422 on request This simplifies configuration and documentation the instrument can be connected to PLC There is also software for this EzControl Delivery An assembly bracket seal self adhesive labels for different units and a manual English German French Spanish are supplied with the instrument Supply voltage 10 30 V DC galvanic isolated polarity protected 90 260 V AC 50 60 Hz Power consumption Max 2 W 6 VA Measurement range Current 0 20 mA 4 20 mA voltage drop max 2 V Voltage 0 10 V 10 to 10 V input imp 1 MΩ max input signal 30 V Control signals High signal 4 30 V DC Display latch Low signal 0 2 V DC Memory 10 years or 1 million memory cycles EEPROM Sensor voltage AC version 10 V DC 2 30 mA and 24 V DC 15 50 mA DC version 10 V DC 2 30 mA Display 5 digits red 14 mm high Display indications Under over the measurement range uuuuu ooooo Display resolution From 0 to 0 0000

    Original URL path: http://www.oem.co.uk/products/Panel/Counters/Kuebler/Kuebler_-_Codix_550_48x96_mm/1158636-303546.html (2016-04-25)