  • Capacitive limit switch - Food NCS-M
    Safety Motors products Pressure Flow Hygienic process instrumentation Point Level Download PDF Skriv ut bild NEGELE Capacitive limit switch Food NCS M Food NCS M Capacitive level switch Measuring range Dk 20 Operating pressure max 10 bar Approvals FDA EHEDG 3 A Application Technical data Ordering information Application specified usage Limit detection of fluid also with low or no water content like syrup fruit concentrates alcohols and oils with a

    Original URL path: http://www.oem.co.uk/products/Pressure_Flow/Hygienic_process_instrumentation/Point_Level/Capacitive_limit_switch_-_Food_NCS-M/2477999-2478381.html (2016-04-25)
    Open archived version from archive


  • Capacitive limit switch - Food NCS
    Machine Safety Motors products Pressure Flow Hygienic process instrumentation Point Level Download PDF Skriv ut bild NEGELE Capacitive limit switch Food NCS Food NCS Capacitive limit switch Measuring range Dk 20 Operating pressure max 10 bar Approvals FDA EHEDG 3 A Application Technical data Ordering information Application specified usage Limit detection of media with low or no water content like syrup fruit concentrates alcohols and oils with a dielectric constant

    Original URL path: http://www.oem.co.uk/products/Pressure_Flow/Hygienic_process_instrumentation/Point_Level/Capacitive_limit_switch_-_Food_NCS/2477999-2478383.html (2016-04-25)
    Open archived version from archive

  • Flow meter FMI. Strong in food, strong in pharma
    NEGELE Magnetic inductive flow meter FMI FMI Magnetic inductive Measuring range 0 1 10 m s Operating pressure 0 1 11 bar absolute Approvals FDA 3 A Application Technical data Ordering information Application specified usage Magnetic inductive flowmeter for the measurement of flow rate and volume in food and pharmaceutical applications Suitable for liquids mash and pastes with a minimum conductivity of 5 μS cm Precise measurement of media containing

    Original URL path: http://www.oem.co.uk/products/Pressure_Flow/Hygienic_process_instrumentation/Flow/Magnetic-inductive_flow_meter_-_FMI/2478005-2478385.html (2016-04-25)
    Open archived version from archive


  • Calorimetric flow switch - FTS-141
    Hygienic process instrumentation Flow Download PDF Skriv ut bild NEGELE Calorimetric flow switch FTS 141 FTS 141 Caliormetric measuring principle Measuring range 10 300 cm s Operating pressure max 60 bar Approvals FDA EHEDG 3 A Application Technical data Ordering information Application specified usage Monitoring of flowing liquids in pipes The monitor can be used to measure liquids that are aqueous water content 50 that do not contain oil and

    Original URL path: http://www.oem.co.uk/products/Pressure_Flow/Hygienic_process_instrumentation/Flow/Calorimetric_flow_switch_-_FTS-141/2478005-2478387.html (2016-04-25)
    Open archived version from archive

  • Ultrasonic flow switch - FWS-141
    process instrumentation Flow Download PDF Skriv ut bild NEGELE Ultrasonic flow switch FWS 141 FWS 141 Ultrasonic doppler principle Measuring range 0 1 2 5 m s Operating pressure max 10 bar Approvals FDA EHEDG 3 A Application Technical data Ordering information Application specified usage Monitoring of flowing liquids in pipes Rough measurement of flow rates and flow volume Suitable for media with turbidity 1 NTU and particle size 50

    Original URL path: http://www.oem.co.uk/products/Pressure_Flow/Hygienic_process_instrumentation/Flow/Ultrasonic_flow_switch_-_FWS-141/2478005-2478389.html (2016-04-25)
    Open archived version from archive

  • Inductive conductivity meter - ILM-2
    conductivity meter ILM 2 Inductive Measuring range 0 999 mS cm Operating pressure max 10 bar Approvals FDA 3 A Application Technical data Ordering information Application specified usage Inductive measurement of the specifi c conductivity of liquid media in the range of 0 999 mS cm Designed for hygienic applications in food beverage and pharmaceutical industries The inductive conductivity meters ILM 2 and ILM 3 will be available until mid

    Original URL path: http://www.oem.co.uk/products/Pressure_Flow/Hygienic_process_instrumentation/Conductivity/Inductive_conductivity_meter_-_ILM-2/2478007-2478391.html (2016-04-25)
    Open archived version from archive

  • ILM-4 conductivity sensor
    to 130 C All parameter adjustments can be made on the device display or via a PC Freely selectable and combined outputs conductivity temperature concentration Compact only 67mm depth behind panel Rapid temperature response t90 15 s Application Technical data Ordering information The ILM 4 is ideally suited for phase separation in CIP clean in place plants With its modular design giving maximum flexibility components can be replaced on site

    Original URL path: http://www.oem.co.uk/products/Pressure_Flow/Hygienic_process_instrumentation/Conductivity/ILM-4_conductivity_sensor/2478007-2518474.html (2016-04-25)
    Open archived version from archive

  • Turbidity sensor - ITM-3
    Turbidity Industrial Instrumentation Machine Safety Motors products Pressure Flow Hygienic process instrumentation Turbidity Download PDF Skriv ut bild NEGELE Turbidity sensor ITM 3 ITM 3 Infrared backscatter principle Measuring range 0 2000 NTU 0 500 EBC Operating pressure max 16 bar Approvals FDA 3 A Application Technical data Ordering information Application specified usage Media with a turbidity 2000 NTU 500 EBC equal to about 5 5 of display ITM 3

    Original URL path: http://www.oem.co.uk/products/Pressure_Flow/Hygienic_process_instrumentation/Turbidity/Turbidity_sensor_-_ITM-3/2478001-2478393.html (2016-04-25)