web-archive-uk.com


Web directory, archive
Search web-archive-uk.com:


Find domain in archive system:
web-archive-uk.com » UK » O » OEM.CO.UK

Total: 482

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • Control unit 352.4/362.0
    on motorised gates which in line with the standard must have relays conforming to safety category 3 A low current is transmitted from the control unit connectors Z1 and Z2 through the sensing strip and a closed circuit is formed via a resistor 8 2 kΩ The control unit outputs cuts the power if anyone anything presses the sensing strip and also following a short circuit or open circuit Supply voltage 24 V AC DC 230 V AC Tolerance 15 to 10 Consumption operation 4 W Relay outputs Safe 2 NO single Signal 1 CO Max contact voltage 250 V AC 24 V DC Max contact current 6 A AC 2 A DC Fuse outputs 4 A Disconnection time 15 ms Max length of sensing strip 100 m Max cable length to the sensing strip 50 m min 0 5 m 2 Status indication 6xLED Cable connection 2xPG9 and 2xPG11 included Ingress protection class IP65 Ambient temperature 20 C to 55 C Installation 4xM5 Mechanical service life 3x10 7 Safety category 3 in accordance with EN954 1 Standard EN1760 2 ZH1 494 Conforming to MD LVD EMC Approvals Skriv ut bild Skriv ut bild Technical characteristics Depending on safety requirements Force guided contacts Internal external redundancy User benefits Status indication Safety category 3 in accordance with EN954 1 Skriv ut bild Strip activated 2 NO and 1 CO output Skriv ut bild Fault in the safety circuit Contact load 4A Skriv ut bild Output activated LED status indication Monitoring of external contactors mm Skriv ut bild 352 4 One input 362 0 Two inputs Skriv ut bild Skriv ut bild 1 One sensing strip Manual reset Monitoring of external contactors 4 Two sensing strips Automatic reset Skriv ut bild Skriv ut bild 2 One sensing strip Automatic reset Monitoring of

    Original URL path: http://www.oem.co.uk/products/Machine_Safety/Resistive_safe_edge/Control_unit_352_4_362_0/1158459-304582.html (2016-04-25)
    Open archived version from archive

  • Control unit 452.4/462.4
    from the control unit connectors Z1 and Z2 through the sensing strip and a closed circuit is formed via a resistor 8 2 kΩ The control units outputs cut the power if anyone anything presses the sensing strip and also following a short circuit or open circuit Supply voltage 24 V AC DC 230 V AC Tolerance 15 to 10 Consumption operation 3 W Relay outputs Safe 2 NO single Signal 1 CO Max contact voltage 250 V AC 24 V DC Max contact current 4 A AC 2 A DC Fuse outputs 4 A Disconnection time 15 ms Max length of sensing strip 100 m Max cable length to the sensing strip 50 m min 0 5 m² Status indication 4xLED Ingress protection class Terminal block IP20 Enclosure IP40 Ambient temperature 20 C to 55 C Installation DIN rail Mechanical service life 3x10 7 Safety category 3 in accordance with EN954 1 Standard EN1760 2 ZH1 494 Conforming to MD LVD EMC Approvals Skriv ut bild Skriv ut bild Technical characteristics Depending on safety requirements Force guided contacts Internal external redundancy User benefits Status indication Safety category 3 in accordance with EN954 1 2 NO and 1 CO output Skriv ut bild Strip activated Contact load 4 A Skriv ut bild Fault in the safety circuit LED status indication Skriv ut bild Output activated Monitoring of external contactors Skriv ut bild Output activated mm Skriv ut bild 452 4 One input 462 4 Two inputs Skriv ut bild Skriv ut bild 1 One sensing strip Manual reset Monitoring of external contactors 4 Two sensing strips Manual reset Monitoring of external contactors Skriv ut bild Skriv ut bild 2 One sensing strip Automatic reset Monitoring of external contactors 5 Two sensing strips Automatic reset Monitoring of external contactors Skriv ut

    Original URL path: http://www.oem.co.uk/products/Machine_Safety/Resistive_safe_edge/Control_unit_452_4_462_4/1158459-304594.html (2016-04-25)
    Open archived version from archive

  • Control unit B412.0
    output Automatic reset Safety category 1 in accordance with EN954 1 Range of application Technical data Dimensions Connection Order number Small control unit for the monitoring of sensing strips in less dangerous applications It fulfils safety category 1 which means that it may only be used in applications in which the risk of injury is only for slight normally reversible injuries If there is any doubt select one of the control units on the following pages A low current is transmitted from the unit s connectors Z1 Z2 through the sensing strip and a closed circuit is formed via a resistor 8 2 kΩ The control unit output cuts the power if anyone anything presses the sensing strip and also following a short circuit or open circuit Supply voltage 24 V AC DC 230 V AC Tolerance 15 to 10 Consumption operation 3 W Relay outputs Safe 1 NO single Max contact voltage 250 V AC 24 V DC Max contact current 4 A AC DC Fuse outputs 4 A Disconnection time 10 ms Max length of sensing strip 100 m Max cable length to the sensing strip 50 m min 0 5 m 2 Status indication 3xLED Ingress protection class Terminal block IP20 Enclosure IP40 Ambient temperature 20 C to 55 C Installation DIN rail Mechanical service life 3x10 7 Safety category 1 in accordance with EN954 1 Standard EN1760 2 Conforming to MD LVD EMC Approvals Skriv ut bild Skriv ut bild Technical characteristics Depending on safety requirements Force guided contacts Internal external redundancy User benefits Status indication Safety category 1 in accordance with EN954 1 Skriv ut bild Strip activated Small installation dimensions Skriv ut bild Fault in the safety circuit LED status indication Skriv ut bild Output activated mm Skriv ut bild Skriv ut bild Skriv

    Original URL path: http://www.oem.co.uk/products/Machine_Safety/Resistive_safe_edge/Control_unit_B412_0/1158459-304597.html (2016-04-25)
    Open archived version from archive

  • Technical information
    please call us on 0116 284 9900 Panel Pressure Flow Machine Safety Connection Systems Encoders Identification Non contact safety switches Resistive safe edge Safety light barriers Technical information Finger Hand Presence Body Control units Safety photocells Accessories Safety relays Sensors Switches Vision systems Motors Show searchresults as Boxes List Technical information Datalogic General information Datalogic General information Datalogic Selection Guide and General Information Datalogic Selection Guide and General Information Selection

    Original URL path: http://www.oem.co.uk/products/Machine_Safety/Safety_light_barriers/Technical_information/1158469.html (2016-04-25)
    Open archived version from archive

  • Finger
    please call us on 0116 284 9900 Panel Pressure Flow Machine Safety Connection Systems Encoders Identification Non contact safety switches Resistive safe edge Safety light barriers Technical information Finger Hand Presence Body Control units Safety photocells Accessories Safety relays Sensors Switches Vision systems Motors Show searchresults as Boxes List Finger DATALOGIC SG4 Finger DATALOGIC SG4 Finger Range up to 6 m Protective field 150 1 800 mm Type 4 or

    Original URL path: http://www.oem.co.uk/products/Machine_Safety/Safety_light_barriers/Finger/1158471.html (2016-04-25)
    Open archived version from archive

  • Hand
    as Boxes List Hand DATALOGIC SG2 B 30 hand DATALOGIC SG2 B 30 hand Hand protection R 30 Type 2 PL d Range up to 19 m Protective height 150 1800 mm DATALOGIC SG2 E 30 hand DATALOGIC SG2 E 30 hand Hand protection R 30 Type 2 PL d Anti interference function 0 2 9 m 0 2 19 m Protective height 150 1800 mm DATALOGIC SG4 Hand DATALOGIC

    Original URL path: http://www.oem.co.uk/products/Machine_Safety/Safety_light_barriers/Hand/1158473.html (2016-04-25)
    Open archived version from archive

  • Presence
    switches Resistive safe edge Safety light barriers Technical information Finger Hand Presence Body Control units Safety photocells Accessories Safety relays Sensors Switches Vision systems Motors Show searchresults as Boxes List Presence DATALOGIC SG2 B 50 90 DATALOGIC SG2 B 50 90 Presence control R 50 90 Type 2 PL d Range up to 19 m Protective height 300 1800 mm DATALOGIC SG2 E 50 90 presence DATALOGIC SG2 E 50

    Original URL path: http://www.oem.co.uk/products/Machine_Safety/Safety_light_barriers/Presence/1158477.html (2016-04-25)
    Open archived version from archive

  • Body
    DATALOGIC SG2 Body big base Body protection 2 3 and 4 beam Type 4 PL d LONG range 0 5 60 m Protective height 500 800 900 1200 mm DATALOGIC SG2 Body compact base DATALOGIC SG2 Body compact base Body protection 2 3 and 4 beam Type 2 PL d Range 0 5 50 m Protective height 500 800 900 1200 mm DATALOGIC SG2 Body compact muting DATALOGIC SG2 Body compact muting Body protection 2 3 and 4 beam Type 2 PL d Muting function integrated also T and L arms Range 0 5 50 m DATALOGIC SG4 Body BIG base DATALOGIC SG4 Body BIG base Body protection 2 3 and 4 beam Type 4 PL e LONG range 6 60 m Protective height 500 800 900 1200 mm DATALOGIC SG4 Body compact base DATALOGIC SG4 Body compact base Body protection 2 3 and 4 beam Type 4 PL e Range 0 5 50 m Protective height 500 800 900 1200 mm DATALOGIC SG4 Body BIG muting DATALOGIC SG4 Body BIG muting Body protection 2 3 and 4 beam Type 4 PL e Advanced Muting functions integrated Range 0 5 60 m DATALOGIC SG4 Body BIG reflector base DATALOGIC SG4

    Original URL path: http://www.oem.co.uk/products/Machine_Safety/Safety_light_barriers/Body/1158475.html (2016-04-25)
    Open archived version from archive



  •  