web-archive-uk.com


Web directory, archive
Search web-archive-uk.com:


Find domain in archive system:
web-archive-uk.com » UK » O » OLSON.CO.UK

Total: 212

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • Sequential Start Master Modules
    This range of products features integral power switching By utilising smart switching technology this device automatically powers up pairs of sockets sequentially on the module reducing power surges on your system and protecting your equipment More than one sequential module can be linked together in line up to a maximum of 16A loading When linked together the power is sequentially turned on every second to each pair of sockets in

    Original URL path: http://www.olson.co.uk/sequential_integral.htm (2016-04-25)
    Open archived version from archive


  • Sequential Start Master Modules
    with 16A double pole MCB type C and protective cover Maximum output current per socket 16A 16A double pole MCB with cover High integrity dual earthing Voltage 230V AC All metal construction Overall dimensions 80x120x422mm Matching Wieland connectors are available separately Patent No GB2390237 Type Description 444 16 Sequential Master with 4 Wieland Connectors switched at 1 sec intervals 16A DP MCB 32A Master Module High power 4 Wieland sockets are switched on at 1 second intervals minimising high in rush currents Module protected with 32A double pole MCB type C and protective transparent cover Maximum output current per socket 16A 32A double pole MCB with cover Total maximum output current 32A High integrity dual earthing Voltage 230V AC All metal construction Overall dimensions 105x200x377mm Matching Wieland connectors are available separately Patent No GB2390237 Type Description 444 32 Sequential Master with 4 Wieland Connectors switched at 1 sec intervals 32A DP MCB Sequential Start power switching Master Module This product is used with EXISTING power distribution units When fitted in line with existing units the module automatically switches each unit on in line at one second intervals providing all the benefits of Sequential Start technology WITHOUT having to change your

    Original URL path: http://www.olson.co.uk/sequential_master.htm (2016-04-25)
    Open archived version from archive

  • Sequential Start Power Module
    dual earthing Voltage 230V AC Input connector IEC309 32A with 3m of cable Options IEC309 16A or UK 13A plugs Different cable length SEQUENTIAL START POWER MODULE WITH ADJUSTABLE START PER SOCKET Type Description SEQ ADJ 32 4 off 13A sockets 32A IEC309 BS4343 Plug and 3m cable picture shows 1m Technical Data 32A Plug IEC309 BS4343 UK 13A Sockets BS 1363 Operating voltage 250V max Approved to EN 60950

    Original URL path: http://www.olson.co.uk/sequential_power.htm (2016-04-25)
    Open archived version from archive


  • Sequential Start why do I need it?
    units draw power from the mains in one surge this huge draw on the power supply can cause potentially damaging surges Olson Sequential Start Power products reduce total in rush currents to a minimum The more installations you have the greater the benefit Olson Sequential Start Systems will give you Olson Electronics Ltd Olson House 490 Honeypot Lane Stanmore Middx HA7 1JY email sales olson co uk Tel 44 0

    Original URL path: http://www.olson.co.uk/sequential_why.htm (2016-04-25)
    Open archived version from archive

  • Automatic Transfer Switches

    (No additional info available in detailed archive for this subpage)
    Original URL path: /ats_f_16.htm (2016-04-25)


  • Power for Desks 1
    of Sockets 4001 Two 13A sockets individually fused and switched with the sockets mounted at 90 and 270 to normal 2 4002 Two 13A sockets individually fused unswitched with the sockets mounted at 90 and 270 to normal 2 4003 Two 13A sockets individually fused and switched 2 Unit Dimensions Technical Data 13 Amp sockets BS 1363 Current rating 13A max Panel mounted fuse holders BS 5733 Operating Voltage 250V

    Original URL path: http://www.olson.co.uk/office_01.htm (2016-04-25)
    Open archived version from archive

  • Power for Desks 2
    rating Individually fused sockets Brackets on each side for easy fixing installation Earth bonded with external M5 earth stud with 250mm long earth lead for maximum safety Optional illuminated mains on off switch All units have Wieland connectors at each end Suitable Wieland connectors available separately Distribution Panel with Individually Fused Sockets Item No of Sockets Dimension in mm A B 4022 2 279 263 4023 3 349 333 4024 4 419 403 4025 5 489 473 4026 6 559 543 Distribution Panel with Individually Fused Sockets and Illuminated On Off Switch Item No of Sockets Dimension in mm A B 4032 2 354 338 4033 3 424 408 4034 4 494 478 4035 5 564 548 4036 6 634 618 Unit Dimensions Technical Data 13 Amp sockets BS 1363 German Sockets VDE 45119 Current rating 13A max Panel mounted fuse holders BS 5733 Double pole on off switch 16A 250V max 100A inrush Operating Voltage 250V AC Manufactured to BS 5733 and BS 6396 Approved to EN 60950 CE RoHS Compliant No of Sockets Fuse Rating 2 5A 3 5A 4 5A 5 3 15A 6 3 15A Olson Electronics Ltd Olson House 490 Honeypot Lane Stanmore Middx HA7

    Original URL path: http://www.olson.co.uk/office_02.htm (2016-04-25)
    Open archived version from archive

  • Power for Desks 3
    5mm² 20A rating Single mains illuminated fuse Brackets on each side for easy fixing installation Earth bonded with external M5 earth stud with 250mm long earth lead for maximum safety Optional illuminated mains on off switch All units have Wieland connectors at each end Suitable Wieland connectors available separately Distribution Panel with Illuminated Fuse Item No of Sockets Dimension in mm A B 4042 2 354 338 4043 3 424 408 4044 4 494 478 4045 5 564 548 4046 6 634 618 Distribution Panel with Illuminated Fuse and Illuminated On Off Switch Item No of Sockets Dimension in mm A B 4052 2 354 338 4053 3 424 408 4054 4 494 478 4055 5 564 548 4056 6 634 618 Unit Dimensions Technical Data 13 Amp sockets BS 1363 German Sockets VDE 45119 Current rating 13A max Panel mounted fuse holders BS 5733 Double pole on off switch 16A 250V max 100A inrush Operating Voltage 250V AC Manufactured to BS 5733 and BS 6396 Approved to EN 60950 CE RoHS Compliant No of Sockets Fuse Rating 2 7A 3 7A 4 7A 5 7A 6 7A Olson Electronics Ltd Olson House 490 Honeypot Lane Stanmore Middx HA7 1JY

    Original URL path: http://www.olson.co.uk/office_03.htm (2016-04-25)
    Open archived version from archive



  •  