  • Quality, cost effective PAT Testing Courses for beginners delivered at your premises
    Exemplar Healthcare Speedy Thames Valley Probation Service Ministry of Defence British Army IKEA Daniel Contractors Ltd Pipetech Utilities Ltd Castle Fire Ltd Scarborough 6th Form College Aziza UK Cygnet Hospital Kensite Services Ltd Sleaford District Furniture Recycling Project Dental Hygienics and Decontamination Intelligent Safety Testing Purite Ltd Swansea Recycling Donation Centre Feversham College Sopwell House Hotel B M Stores Rotherham MBC Warwickshire County Council Lowestoft 6th Form College Serco Lasermet Ltd Intertek Mark Powell Mechanical Services Ltd Gilmor Hair Beauty The Bed Factory Hotels Ltd Heyford House Ltd Dalycom MB Rooke Sons National Trust KPS Electrics Western Power Distribution Thornton Property Services Ltd North Leamington School Beck Pollitzer UK Sony DADC UK Ltd Advanced Engineering Ltd Tweets by prioryacademy PAT Testing Courses for Beginners PAT Testing 2 Day Course For your convenience we deliver the training at your premises 229 00 VAT for 1 309 00 VAT for 2 389 00 VAT for 4 10 Discount Schools Charities 206 10 VAT for 1 278 10 VAT for 2 350 10 VAT for 4 Priory Training Academy are a national training company with many years of practical PAT Testing experience as well as training people in PAT Testing We carry out PAT Testing Courses throughout England and Wales normally at your premises YES WE COME TO YOU so there should be no difficulties for you getting to your training venue We don t charge you for our fuel or accommodation let that be our problem not yours All of the following are included FREE with this course Personalised Certificate On going Support Comprehensive Course Notes PAT Testing On site Guide Why train with Priory Training Academy At Priory we only employ qualified Instructors with extensive PAT Testing experience in a multitude of environments To be able to share their knowledge our Instructors need to know their subject inside out let s face it they will never know what question they will be asked next Our PAT Tester Courses are intensive electrical safety is a complex subject However your course instructor will take you through the processes in a logical manner at a pace to suit you As PAT Testing is based upon guidelines and best practice you ll begin by learning the origins of PAT Testing and its importance in your workplace On top of this comes basic electrical theory the design of appliances and the role of manufacturers when dealing with electrical safety Once you know how an appliance has been constructed you can determine what tests can be carried out and what the test equipment actually does to the appliance Once we have covered the theory you will progress onto putting the theory into practice The afternoon session is your chance to get your hands on the test equipment and appliances some of which may have faults in order to test your understanding By covering a variety of appliances we can start to personalise the training and make it relate to the appliances at your premises Whilst we cannot

    Original URL path: http://www.prioryconsultants.co.uk/ (2016-02-17)
    Open archived version from archive


  • PAT Testing Training Courses in England and Wales
    All PAT Testing Training Course prices for Schools and Colleges 10 OFF All PAT Testing Training Course prices for Registered Charities PAT Testing Course Content Equipment Construction Types of equipment and classification marks Show how electric shock can occur through lack of basic protection or inadequate fault protection Explain how the different equipment construction types provide protection State the effect of cord set and extension lead earth resistance on disconnection times under earth fault conditions State the need for RCD protection Inspection User Check Formal Visual Inspection Environmental suitability of equipment Good housekeeping Suitability of equipment Switching of equipment and isolation from the electrical supply Condition of equipment and supply cord Combined Inspection and Test Identify items that users should be competent to inspect Combined Inspection and Testing Factors to be considered when conducting visual inspections of electrical equipment The purpose of the electrical tests Earth Continuity Insulation Resistance Earth Leakage Touch Current Substitute Leakage Function Load Polarity RCD Test on Extension Leads Which tests should not be carried out Test instruments The Use of Instruments and Recording Data Identify minimum and maximum acceptable conductor and insulation resistances along with leakage and touch currents Requirements for identification labels Interpretation of results to identify deterioration Procedures to deal with damaged and faulty equipment Considerations for appliance couplers and cords sets Considerations for IT equipment with high protective conductor currents and testing limitations Overcurrent protection and plug fuses Tests that may be required following equipment repair Practical Inspection and Testing Fault finding identification Instruction on inspecting and testing the user s own electrical equipment Instruction on using the user s own test instruments Identification of standards and kite marks Frequency of Inspection Testing PAT Testing Course Suitability Whilst an electrical background certainly isn t necessary an understanding of basic electrical principals will help the trainee although these can be incorporated into the course as required To be a successful PAT Tester you need technical ability common sense a good eye for detail and a good attitude Some of these we can teach but some are linked to your personality All we ask is for the delegates to take part in the training and give us 100 We would suggest that all delegates attempt our PAT Testing Quiz to help them prepare Doing this bit of homework significantly improves your chances of passing the course Attending a PAT course can be great for re training or embarking on a new career Also it doesn t require any prior electrical training or knowledge to get you started What you will need To be at least 18 years old Good colour vision not colour blind Good English Language Maths GCSE level is normally sufficient If English isn t your first language don t be put off but please be aware that you will need a good level of written and verbal English we need to be able to converse with and assess delegates throughout the day Excellent attention to detail The ability and willingness to

    Original URL path: http://www.prioryconsultants.co.uk/pat-testing-courses.html (2016-02-17)
    Open archived version from archive

  • PAT Testing Quiz - Test your PAT knowledge for free
    Watford St Albans Hemel Hempstead Stevenage Huntingdonshire Huntingdon St Ives St Neots Ramsey Yaxley Kent Maidstone Canterbury Bromley Rochester Margate Folkestone Dover Greenwich Lancashire Lancaster Liverpool Manchester Preston Bolton Warrington Leicestershire Leicester Loughborough Melton Mowbray Coalville Lutterworth Lincolnshire Lincoln Grimsby Scunthorpe Boston Grantham Middlesex Norfolk Norwich Great Yarmouth King s Lynn Dereham Cromer Hunstanton Northamptonshire Northampton Peterborough Corby Kettering Wellingborough Nottinghamshire Nottingham Mansfield Worksop Newark Retford Southwell Oxfordshire Oxford Banbury Witney Bicester Henley on Thames Carterton Thame Rutland Oakham Uppingham Cottesmore Shropshire Shrewsbury Telford Oswestry Whitchurch Market Drayton Ludlow Somerset Taunton Bath Weston super Mare Yeovil Bridgwater Wells Glastonbury Staffordshire Stafford Stoke on Trent Wolverhampton Walsall Cannock Lichfield Suffolk Ipswich Bury St Edmunds Lowestoft Felixstowe Sudbury Haverhill Bungay Surrey Guildford Croydon Woking Sutton Kingston on Thames Wimbledon Sussex Chichester Brighton Worthing Crawley Hastings Eastbourne Horsham Warwickshire Warwick Birmingham Coventry Nuneaton Rugby Solihull Stratford upon Avon Wiltshire Trowbridge Salisbury Swindon Chippenham Devizes Marlborough Warminster Worcestershire Worcester Dudley Kidderminster Stourbridge Halesowen Malvern Evesham Yorkshire North Riding Northallerton Middlesbrough Scarborough Whitby East Riding Beverley Hull Bridlington Driffield Hornsea Filey West Riding Wakefield Leeds Sheffield Bradford Halifax Harrogate York South Wales Cardiff Newport Swansea Neath North Wales North London South London East London West London Central London Home PAT Testing Courses PAT Testing Quiz PAT Testing Basics Which Course What do we need Contact Us 3 2 1 The first quiz below is designed to test your basic electrical knowledge There are 20 questions each with a single correct answer If you don t get everything right at the first attempt have another go If the Introduction Page doesn t load within 10 seconds either you have a slower than normal internet connection speed or your computer doesn t have Adobe Flash Player installed This can be downloaded FREE from http get adobe com

    Original URL path: http://www.prioryconsultants.co.uk/pat-quiz.html (2016-02-17)
    Open archived version from archive


  • PAT Testing Basics
    used the appliance has been made to the correct European Standard the Class of the appliance whether the plug and fuse carry the correct BS numbers the suitability of the appliance for the environment ingress protection rating where necessary and many more Due to the technical nature of the Formal Visual Inspection it is normally carried out by a suitably trained member of staff or PAT contractor The results of a Formal Visual Inspection are to be recorded irrespective of the results obtained i e whether the appliance has passed or failed If carried out correctly the Formal Visual Inspection will identify up to 95 of appliance failures whereas the electrical tests will only find around 5 of appliance problems Click here for more information The PAT Tests we carry out are designed to measure the quality of the safety devices built into appliances and their ability to protect the user from harm One specific safety feature is an earth path Some appliances have exposed metal parts which may become live should the appliance develop a fault This in turn could lead to an electric shock for the user if they touch these parts To help prevent this an extra wire is added to the appliance by the manufacturer which connects the metal parts of the appliance to the protective earthing conductor in the fixed installation If the appliance develops a fault and the metal parts become live the fault current should pass from the metal parts down the earth wire into the mains wiring of the building and to safety An appliance with a protective earthing conductor earth wire is known as Class I The Earth Continuity Test uses a test current which is applied to exposed metal parts of the appliance thus simulating a fault in the appliance If the earth wire in the appliance is present and in good condition the test current should go from the metal parts down the earth wire to the PAT Test equipment which displays the test results as a resistance value measured in Ohms Ω The engineer should use their skills and known values to determine whether the test results are acceptable for the appliance Typical results are between 0 01Ω and 0 10Ω for an appliance with a short lead rising to values in excess of 0 30Ω for longer extension leads Maximum values do apply and must be observed at all times Click here for more information Insulation is described as any non conductive material being used to keep the appliance user away from live parts within the appliance thus reducing the risk of electric shock It can be anything from modern materials such as plastic or silicone through to more traditional materials such as wood or even air The quality of the material being used needs to be very good for obvious reasons but over time it may deteriorate with age and use The Insulation Resistance Test is designed to measure the quality of the insulation surrounding live

    Original URL path: http://www.prioryconsultants.co.uk/pat-testing-basics.html (2016-02-17)
    Open archived version from archive

  • Which PAT Testing Course
    time designing and delivering a multitude of training courses for many different industries through their own training centres or approved training providers Their courses are generally very good and are well respected but they are often designed for people with previous qualifications or experience in a particular industry For example the notes for the C G 2377 state that their course is aimed at practicing electricians and this qualification will help and progress individuals within the Electrotechnical industry Obviously if you are a practicing electrician this may be a useful addition to your qualifications However if not you may find this course is too difficult as it will be assumed that you have a level of electrical knowledge already The trainee will have their understanding tested via a practical skills test and theory examination PAT Testing Competency Course In house Many people believe the myth that PAT Testing must be carried out by a qualified electrician whereas in fact the person carrying out the role must be a competent person Whilst there is some electrical content within PAT Testing role the bulk of the role is more associated with commonsense and Health Safety A good in house course will be based upon the recognised text for PAT Testing the Code of Practice for In service Inspection Testing of Electrical Equipment latest edition the same text which the City Guilds 2377 course is based upon However the course will be tailored to suit the needs of the client For example someone tasked with PAT Testing in a primary school wouldn t necessarily need to know how to inspect and test a 3 phase motorised item more associated with a factory environment Once the basics of PAT Testing are understood they can be applied to all electrical equipment The role isn t as complicated as you may think but it does require commonsense the right attitude a level of technical ability attention to detail and the ability and willingness to follow a method of working to its conclusion The trainee will have their understanding tested via a practical skills test and theory examination Online or DVD based PAT Testing Course Arguably these courses hold the least amount of value as they are ultimately a guaranteed pass for the minimum amount of effort Basic subject matter is provided and the trainee works through the modules at their own pace At the end of each module there will be a test before moving onto the next module If the trainee fails they simply go through the module as many times as necessary in order to pass At the end of the course will be a final test Upon completion of the course a certificate will be issued At no stage is there any interaction with an instructor so what tends to happen is the trainee will simply learn the answers to the questions by trial and error rather than asking for help and gaining an understanding of the answer which can then be applied

    Original URL path: http://www.prioryconsultants.co.uk/which-course.html (2016-02-17)
    Open archived version from archive

  • PAT Test Equipment
    Run leakage at 230V Single rotary dial position initiates test sequence Class I IT 200mA Earth Bond Class I 20A Earth Bond Class II Extension lead test including polarity Tests 110V appliances for earth bond and insulation with appropriate test adaptor Also includes Plug Wiring Vinyl Tape 25mm X 66m To attach to appliances with rewirable plugs 500 x PASS Labels 250 x FAIL Labels 10 x BS1363 Plugs 20 x BS1362 3A Fuses 20 x BS1362 5A Fuses 10 x BS1362 13A Fuses Insulated Screwdriver Set Wire Stripper Cloverleaf Adapter Log Sheet Pack Kewtech KT71 Portable Appliance Tester Kit 3 Equipment Re seller e g Charity Shop 12 00 P P VAT BS1362 Plug Fuse Pack 3A Red 5A Black 13A Brown Pack includes 20 of each rating 11 00 P P VAT BS1363 Plug Pack 3 pin Plug made to BS1363 Rated at 13A Fitted with a 3A BS1362 Fuse Pack of 10 Suitable for testing IT and all other appliances 250V 500V insulation test voltages Run leakage at 230V Single rotary dial position initiates test sequence Class I IT 200mA Earth Bond Class I 20A Earth Bond Class II Extension lead test including polarity Tests 110V appliances for earth bond and insulation with appropriate test adaptor Also includes Kewtech Loopcheck 107 Advanced Socket Tester 500 x PASS Labels 250 x FAIL Labels 5 x BS1363 Plugs 10 x BS1362 3A Fuses 10 x BS1362 5A Fuses 10 x BS1362 13A Fuses Insulated Screwdriver Set Wire Stripper Cloverleaf Adapter Log Sheet Pack Kewtech KT71 Portable Appliance Tester Kit 1 Everything you need to get you started Kewtech Loopcheck 107 Advanced Socket Tester A standard socket tester does not check for the quality of the earth connection and cannot detect a neutral live reverse at the incoming supply the Kewtech 107 does Key Features Checks correct socket outlet wiring Checks the quality of the earthing that is essential for safe installations Checks for the polarity of the mains supply Checks RCDs with measured current Bright LEDs Easy to use anything other than green needs checking out This plug wiring tape is designed to fix easily around flexible cables on appliances and extension leads etc Attach to new or reconditioned equipment Helps you comply with PUWER 1998 which requires warning labels to enable the correct installation safe operation and maintenance of work equipment Supplied in 25mm wide x 66 metre long rolls Approximately 440 repeats of the plug wiring diagram illustrated on each roll each one measures 115 x 25mm 19 00 P P VAT Plug Wiring Vinyl Tape Industrial equipment i e not on a standard 3 pin plug are also covered under the IET Code of Practice To be able to test them they need to be plugged into your test equipment These handy adapters will allow you test test 110V 230V and 415V equipment and leads to the required standard 110V Plug Socket Test Lead 16A 32A 230V Plug Socket Test Lead 16A 32A 415V Plug Socket

    Original URL path: http://www.prioryconsultants.co.uk/pat_test_equipment.html (2016-02-17)
    Open archived version from archive

  • Priory Training Academy - Contact Us
    Albans Hemel Hempstead Stevenage Huntingdonshire Huntingdon St Ives St Neots Ramsey Yaxley Kent Maidstone Canterbury Bromley Rochester Margate Folkestone Dover Greenwich Lancashire Lancaster Liverpool Manchester Preston Bolton Warrington Leicestershire Leicester Loughborough Melton Mowbray Coalville Lutterworth Lincolnshire Lincoln Grimsby Scunthorpe Boston Grantham Middlesex Norfolk Norwich Great Yarmouth King s Lynn Dereham Cromer Hunstanton Northamptonshire Northampton Peterborough Corby Kettering Wellingborough Nottinghamshire Nottingham Mansfield Worksop Newark Retford Southwell Oxfordshire Oxford Banbury Witney Bicester Henley on Thames Carterton Thame Rutland Oakham Uppingham Cottesmore Shropshire Shrewsbury Telford Oswestry Whitchurch Market Drayton Ludlow Somerset Taunton Bath Weston super Mare Yeovil Bridgwater Wells Glastonbury Staffordshire Stafford Stoke on Trent Wolverhampton Walsall Cannock Lichfield Suffolk Ipswich Bury St Edmunds Lowestoft Felixstowe Sudbury Haverhill Bungay Surrey Guildford Croydon Woking Sutton Kingston on Thames Wimbledon Sussex Chichester Brighton Worthing Crawley Hastings Eastbourne Horsham Warwickshire Warwick Birmingham Coventry Nuneaton Rugby Solihull Stratford upon Avon Wiltshire Trowbridge Salisbury Swindon Chippenham Devizes Marlborough Warminster Worcestershire Worcester Dudley Kidderminster Stourbridge Halesowen Malvern Evesham Yorkshire North Riding Northallerton Middlesbrough Scarborough Whitby East Riding Beverley Hull Bridlington Driffield Hornsea Filey West Riding Wakefield Leeds Sheffield Bradford Halifax Harrogate York South Wales Cardiff Newport Swansea Neath North Wales North London South London East London West London Central

    Original URL path: http://www.prioryconsultants.co.uk/contact-us.html (2016-02-17)
    Open archived version from archive

  • What is PAT Testing? - A useful guide to PAT
    carried out in both cases is broadly the same although there is a difference in scale and complexity From this point onwards let us concentrate on PAT Testing and leave the fixed installation to the electricians In service Inspection Testing of Electrical Equipment As most people refer to typical work equipment as portable due to its size and portability maintenance of work equipment has been known as Portable Appliance Testing or PAT Testing for many years In a way it s like calling a vacuum cleaner a Hoover when in fact it may be a Dyson It has become a generic name In reality not all electrical equipment is portable and our role involves more than just testing so we should really use the full name for the role In service Inspection Testing of Electrical Equipment Although it is a much larger and unwieldy name it is much more descriptive and suitable If we break the name down it gives us a better understanding of what the role entails In service The equipment is in use as opposed to electrical equipment which may be on the premises as stock items for sale Inspection Before equipment is tested for electrical safety it should be inspected for damage missing parts added parts equipment information power appliance classification voltage ingress protection rating suitability of use statutory symbols damage to the plugtop flex suitability of the fuse British Standard numbers etc Testing Once equipment has passed a Formal Visual Inspection it can be tested for electrical safety This normally involves putting the equipment through a series of electrical tests using known currents and voltages and taking test results These results are compared to known values to determine whether specific safety features built into the equipment will perform if there is a fault situation Electrical Equipment As we have already identified not all electrical equipment is portable In fact we can break equipment down into several different appliance types based upon how often they are moved their size and the proximity of the equipment user to the equipment For example a drill is classed as hand held as the user holds it when it is in use whereas a fridge is classed as stationary as it doesn t move These different appliance types will help us to determine the potential risks attached to the appliance and how often we need to carry out inspections and tests on the equipment The PAT Testing Process PAT Testing is relatively simple but in order to carry it out correctly the PAT Tester must be organised disciplined and be able to follow a process We can teach the technical side of PAT Testing but we can t change a bad attitude Environment Check This is to do with the safety of the PAT Tester and also the safety of the user Upon entering the room a PAT Tester should have a good look around at the overall safety of the environment For example is the equipment being used for

    Original URL path: http://www.prioryconsultants.co.uk/what-is-pat-testing.html (2016-02-17)