web-archive-uk.com


Web directory, archive
Search web-archive-uk.com:


Find domain in archive system:
web-archive-uk.com » UK » R » RIGOL-UK.CO.UK

Total: 244

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • Rigol DSA832-TG 3.2GHz Spectrum Analyser with Tracking Generator
    Level Axis Logarithmic Scale 1dB to 200dB Linear Scale 0 to Reference Level Number of Display Points 601 Number of Traces 3 Math Trace Trace Detectors Normal Positive Peak Negative Peak Sample RMS Voltage Average Quasi Peak with EMI DSA800 option Trace Functions Clear Write Max Hold Min Hold Average View Blank Units dBm dBmV dBμV nV μV mV V nW μW mW W Dimensions W x H x D 362mm x 179mm x 128mm Weight 4 25kg 4 55kg without tracking generator 5 15kg with tracking generator Tracking Generator Model DSA815 TG Only DSA832 TG Only DSA875 TG Only Frequency Range 100kHz to 1 5GHz 100kHz to 3 2GHz 100kHz to 7 5GHz Output Level Range 20dBm to 0dBm 30dBm to 0dBm Output Level Resolution 1dB Note 1 3dB bandwidth RBW Uncertainty 5 nominal RBW Shape Factor 60dB 30dB 5 nominal Note 2 Attenuation 30dB Note 3 When fc 10MHz input level 25dBm and PA is off the protection switch will be on Note 4 fc 50MHz Peak Detector PA Off Attenuation 10dB Input Signal Level 10dBm 20⁰C to 30⁰C Note 5 95 confidence level S N 20dB RBW VBW 1kHz preamplifier off 10dB RF attenuation 50dBm RF 0dBm fc 10MHz 20⁰C to 30⁰C Note 6 20⁰C to 30⁰C fc 1GHz Note 7 0dB RF Attenuation RBW VBW 100Hz sample detector trace average 50 20⁰C to 30⁰C input terminated 50Ω Note 8 A PA is optional on the following models DSA832 DSA832 TG DSA875 DSA875 TG Documents Rigol DSA800 Series Datasheet Rigol DSA800 Series User Guide Rigol DSA800 Series Programming Guide Rigol DSA800 Series Options Accessories PC Software To download Rigol Ultra Sigma PC software CLICK HERE Rigol Ultra Sigma Overview To download Rigol Ultra Spectrum PC software CLICK HERE Rigol Ultra Spectrum Datasheet To download Rigol EMI Test System PC software CLICK HERE Rigol EMI Test System Datasheet Rigol EMI Test System User Guide Please note The software files are compressed and must be extracted before installation Ultra Sigma must be installed before any other Rigol application To open Ultra Spectrum or the EMI Test System software Open Ultra Sigma then connect your instrument then open Ultra Spectrum or the EMI Test System from within Ultra Sigma To use the EMI Test System Software the Rigol Spectrum Analyser must have an active EMI Filter Quasi Peak Detector licence CHM files must be unblocked from within the file Properties window before use Videos Rigol DSA815 TG Spectrum Analyser Introduction Part 1 Rigol Tech Rigol DSA815 TG Spectrum Analyser Introduction Part 2 Rigol Tech Rigol DSA815 TG Spectrum Analyser Teardown EEVblog 391 Introducing the Rigol DSA875 7 5GHz Spectrum Analyser Telonic Instruments Rigol DSA875 TG Review Teardown and Experiments The Signal Path Blog EMC Pre Compliance Testing Conducted Emissions Rigol DSA815 with EMI Licence Rigol Tech EMC Pre Compliance Testing Conducted Emissions EEVblog 548 EMC Pre Compliance Testing Radiated Emissions Colin O Flynn Front Panel Overview Basic Measurements Trace Function Peak Function Marker Function User Key Measuring Small Signals Measuring

    Original URL path: https://www.rigol-uk.co.uk/Rigol-DSA832-TG-Spectrum-Analyser-p/dsa832-tg.htm (2016-04-25)
    Open archived version from archive


  • Get the latest RIGOL firmware
    and a functional check before despatch to our customers A report is included with your purchase And there s more Did you know that all Rigol instruments arrive in the UK without a UK mains lead The standard mains lead supplied within each package is European At Telonic Instruments we add a UK mains lead and a USB cable where not already supplied by Rigol for free before despatch to our customers Latest official Rigol firmware versions As of 13th April 2016 DG1022 A 00 03 00 DG1000Z 00 01 09 DG4000 00 01 12 DG5000 00 01 10 DM3058 E 02 00 02 DM3068 01 09 00 DP800 00 01 14 DS1000B 00 04 01 DS1000D E 00 04 02 SP1 DS MSO1000Z 00 04 03 SP2 DS MSO2000A 00 03 04 SP2 DS MSO4000 00 02 02 SP5 DS6000 00 02 00 SP5 DSA815 00 01 15 DSA832 00 01 02 DSA875 00 01 02 DSA1000 A 00 01 18 DSG800 00 01 05 DSG3000 00 01 05 M300 00 02 00 06 01 MC3065 06 04 03 03 WARNING This information is published for customer information only Firmware update procedures are subject to change by the manufacturer

    Original URL path: http://www.rigol-uk.co.uk/ProductDetails.asp?ProductCode=FIRMTEST (2016-04-25)
    Open archived version from archive

  • Rigol Electronic Test & Measurement Equipment
    of Stock Form Please fill in our form below to be alerted once the product is back in stock Telonic Instruments Limited can be found at Toutley Industrial Estate Toutley Road Wokingham Berks RG41 1QN U K About Us Company Info Contact Us My Account View Cart Sign In Order Status Products Product Index Category Index Helpful Info Shipping Returns Privacy Policy Terms Conditions Questions Call Us Tel 0118 9786911

    Original URL path: http://www.rigol-uk.co.uk/Articles.asp?ID=267&mod= (2016-04-25)
    Open archived version from archive


  • Rigol MSO2302A 300MHz Mixed Signal Oscilloscope - SPECIAL OFFER!
    A B Falling Edge Connectivity USB Host Device LAN LXI Aux Output TrigOut PassFail Support USB GPIB Optional Display 8 WVGA 800x480 TFT LCD 256 Intensity Grading Level Size WxHxD 361 6mm x 179 6mm x 130 8mm Weight 3 9kg 0 2kg without package Standard Probes RP3300A 350MHz BW Passive Probe 2 sets 1 set RPL2316 LA Probe Built In 2 Channel Waveform Generator S Models Only 2 Channels 200MSa s Sample Rate 14bits Vertical Resolution 25MHz Maximum Output Frequency 20mVpp 5Vpp Amplitude Range High Z 16kpts Waveform Length Standard Waveforms Sine Square Ramp Pulse Noise DC Arbitrary Waveforms Sinc ExpRise ExpFall ECG Gauss Lorentz Haversine User Defined Documents Rigol MSO DS2000A Series Datasheet Rigol MSO DS2000A Series User Guide Rigol MSO DS2000A Series Programming Guide PC Software To download Rigol Ultra Sigma PC software CLICK HERE Rigol Ultra Sigma Overview To download Rigol Ultra Power Analyser PC software CLICK HERE Please note The software files must be extracted before installation Ultra Sigma must be installed before any other Rigol application To open Ultra Power Analyser Open Ultra Sigma then connect your instrument then open Ultra Power Analyser from within Ultra Sigma CHM files must be unblocked from within the file Properties window before use Videos Rigol DS2000A Series Oscilloscopes A Brief Overview Emona Instruments Deep Memory Advantage Abnormal Signal Capture Advanced Maths Functions FFT Function Example Waveform Record Function Recording Specific Frames PassFail Function Measuring Narrow Pulses Pulse Trigger Function Runt Trigger Function Video Trigger Function Nth Edge Trigger Function Windows Trigger Function Slope Trigger Function Duration Trigger Function TimeOut Trigger Function RS232 Bus Analysis I2C Bus Analysis CAN Bus Analysis Features 300MHz bandwidth 2 channel digital oscilloscope with built in logic analyser Maximum sample rate 2GSa s Vertical scale 500μV div to 10V div Selectable 50Ω input impedance Memory depth up to 14Mpts 56Mpts optional Innovative UltraVision technology Up to 50 000wfms s waveform capture rate Up to 65 000 frames real time waveform record replay analysis functions 8 WVGA 800x480 TFT LCD display 256 intensity grading levels Up to 17 off trigger functions including various protocol triggers Auto measurement of 29 waveform parameters with statistics Built in FFT with a choice of window functions Pass fail test function Various waveform math functions Supports internal and external storage of instrument settings waveforms screen images and parameters PictBridge printer support Built in help facility Connectivity USB Host Device LAN LXI AUX Output USB GPIB optional Supplied with 2 off passive probes 350MHz 1 off logic analyser probe set USB cable UK European mains leads quick guide CD user guide application software Options include Deeper memory advanced trigger functions RS232 I2C SPI decoding kit CAN analysis kit rack mount kit soft carry bag RCL standard calibration RCL UKAS calibration Accessories Rigol RP1001C Rigol RM DS2000 Rigol RP6150A Rigol RP1004C Our Price 674 00 808 80 inc VAT Add Our Price 146 00 175 20 inc VAT Add Our Price 243 00 291 60 inc VAT Add Our Price 3

    Original URL path: https://www.rigol-uk.co.uk/Rigol-MSO2302A-Mixed-Signal-Oscilloscope-p/mso2302a.htm (2016-04-25)
    Open archived version from archive

  • Rigol DM3058E 5½ Digit Digital Multimeter
    2 00000V 20Hz 45Hz 1 5 0 10 0 01 0 005 45Hz 20kHz 0 2 0 05 0 01 0 005 20kHz 50kHz 1 0 0 05 0 01 0 005 50kHz 100kHz 3 0 0 05 0 05 0 010 20 0000V 20Hz 45Hz 1 5 0 10 0 01 0 005 45Hz 20kHz 0 2 0 05 0 01 0 005 20kHz 50kHz 1 0 0 05 0 01 0 005 50kHz 100kHz 3 0 0 05 0 05 0 010 200 000V 20Hz 45Hz 1 5 0 10 0 01 0 005 45Hz 20kHz 0 2 0 05 0 01 0 005 20kHz 50kHz 1 0 0 05 0 01 0 005 50kHz 100kHz 3 0 0 05 0 05 0 010 750 000V 20Hz 45Hz 1 5 0 05 0 01 0 005 45Hz 20kHz 0 2 0 05 0 01 0 005 20kHz 50kHz 1 0 0 05 0 01 0 005 50kHz 100kHz 3 0 0 05 0 05 0 010 True RMS AC Current 4 20 0000mA 20Hz 45Hz 1 5 0 10 0 015 0 015 45Hz 2kHz 0 5 0 10 0 015 0 006 2kHz 10kHz 2 5 0 20 0 015 0 006 200 000mA 20Hz 45Hz 1 5 0 10 0 015 0 005 45Hz 2kHz 0 3 0 10 0 015 0 005 2kHz 10kHz 2 5 0 20 0 015 0 005 2 00000A 20Hz 45Hz 1 5 0 20 0 015 0 005 45Hz 2kHz 0 5 0 20 0 015 0 005 2kHz 10kHz 2 5 0 20 0 015 0 005 10 0000A 5 20Hz 45Hz 1 5 0 15 0 015 0 005 45Hz 2kHz 0 5 0 15 0 015 0 005 2kHz 5kHz 2 5 0 20 0 015 0 005 1 Specifications are for 30 minute warm up slow measurement rate and 18 to 28 calibration temperature 2 20 over range on all ranges except DCV 1000V ACV 750V DCI and ACI 10A range 3 Specifications are for 4 wire resistance function or 2 wire resistance using REL operation Without REL operation add 0 2Ω additional errors in 2 wire resistance function 4 For each additional 1 volt over 500VDC add 0 02mV of error 5 For current terminal 7A DC or AC RMS for 30 seconds ON and 30 seconds OFF Documents Rigol DM3058 DM3058E Datasheet Rigol DM3058 DM3058E User Guide Rigol DM3058 DM3058E Programming Guide PC Software To download Rigol Ultra Sigma PC software CLICK HERE Rigol Ultra Sigma Overview To download Rigol Ultra Sensor PC software CLICK HERE To download Rigol Ultra View PC software CLICK HERE Please note Rigol software files must be extracted before installation Ultra Sigma must be installed before any other Rigol application To open Ultra Sensor or Ultra View Open Ultra Sigma then connect your instrument then open Ultra Sensor or Ultra View from within Ultra Sigma CHM files must be unblocked from within the file Properties window before use

    Original URL path: https://www.rigol-uk.co.uk/Rigol-DM3058E-Digital-Multimeter-p/dm3058e.htm (2016-04-25)
    Open archived version from archive

  • Rigol MSO1074Z-S 70MHz Mixed Signal Oscilloscope
    Period Area Freq Period Rise Time Fall Time Width Width Duty Duty Delay A B Rising Edge Delay A B Falling Edge Phase A B Rising Edge Phase A B Falling Edge Connectivity USB Host Device LAN LXI Aux Output TrigOut PassFail Support USB GPIB Optional Display 7 WVGA 800x480 TFT LCD 64 Intensity Grading Level Size WxHxD 313 1mm x 160 8mm x 122 4mm Weight 3 2kg 0 2kg without package Standard Probes RP2200 150MHz BW Passive Probe 4 sets 1 set RPL1116 LA Probe Built In 2 Channel Waveform Generator S Models Only 2 Channels 200MSa s Sample Rate 14bits Vertical Resolution 25MHz Maximum Output Frequency 20mVpp 5Vpp Amplitude Range High Z 16kpts Waveform Length Standard Waveforms Sine Square Ramp Pulse Noise DC Arbitrary Waveforms Sinc ExpRise ExpFall ECG Gauss Lorentz Haversine User Defined Modulation AM FM Documents Rigol MSO DS1000Z Series Datasheet Rigol MSO DS1000Z Series User Guide Rigol MSO DS1000Z Series Programming Guide PC Software To download Rigol Ultra Sigma PC software CLICK HERE Rigol Ultra Sigma Overview To download Rigol Ultra Scope PC software for Rigol MSO DS1000Z oscilloscopes CLICK HERE To download Rigol Ultra Station PC software CLICK HERE Please note The software files must be extracted before installation Ultra Sigma must be installed before any other Rigol application To open Ultra Scope or Ultra Station Open Ultra Sigma then connect your instrument then open Ultra Scope or Ultra Station from within Ultra Sigma CHM files must be unblocked from within the file Properties window before use Videos Rigol DS1054Z Oscilloscope Review EEVblog 703 Rigol DS1000Z Series Review ToolBoom Supermarket Rigol DS1104Z Oscilloscope Exploring its Bandwidth Limits Telonic Instruments Rigol MSO1104Z S Oscilloscope First Impressions EcProjects Deep Memory Advantage Abnormal Signal Capture Advanced Maths Functions FFT Function Example Waveform Record Function Recording Specific Frames PassFail Function Measuring Narrow Pulses Pulse Trigger Function Runt Trigger Function Video Trigger Function Nth Edge Trigger Function Windows Trigger Function Slope Trigger Function Duration Trigger Function TimeOut Trigger Function RS232 Bus Analysis I2C Bus Analysis CAN Bus Analysis Features 70MHz bandwidth 4 channel digital oscilloscope with built in logic analyser and 2 channel 25MHz function arbitrary waveform generator Maximum sample rate 1GSa s Vertical scale 1mV div to 10V div Memory depth up to 12Mpts 24Mpts optional Innovative UltraVision technology Up to 30 000wfms s waveform capture rate Up to 60 000 frames real time waveform record and replay optional 7 WVGA 800x480 TFT LCD display 64 intensity grading levels Up to 15 off trigger functions including various protocol triggers Auto measurement of 33 waveform parameters with statistics Built in FFT with choice of window functions Pass fail test function Built in help facility Connectivity USB Host Device LAN LXI AUX Output USB GPIB optional Compact size light weight easy to use Supplied with 4 off passive probes 150MHz 1 off logic analyser probe set 2 off BNC leads USB cable UK European mains leads quick guide CD user guide application software Options include Deeper memory waveform record

    Original URL path: https://www.rigol-uk.co.uk/Rigol-MSO1074Z-S-Mixed-Signal-Oscilloscope-p/mso1074z-s.htm (2016-04-25)
    Open archived version from archive

  • About Us
    U K Deliveries to Europe take approximately 3 working days We are approved to ISO9001 by NQA National Quality Assurance Telonic carry out quality assessments on all of our suppliers to ensure the highest standards are maintained The History of RIGOL RIGOL Technologies Inc founded in 1998 is an emerging leader in test and measurement and an ISO9001 2008 certified Quality Management System company RIGOL s goal is to be the partner of choice in test and measurement solutions and services Their track record speaks for itself already redefining price performance in several T M product categories With more than 400 employees worldwide RIGOL invests heavily in R D and today has over 100 R D engineers working on future products A network of ten sales offices in China along with a branch office in United States and a branch office in Germany offer products and services in over 60 countries or regions with more than 150 distributors and representatives RIGOL s premium line of products spans Digital Oscilloscopes RF Spectrum Analysers Digital Multimeters Function Arbitrary Waveform Generators Digital Programmable Power Supplies HPLC and UV Vis Spectrophotometers helping engineers researchers educators alike to address their measurement challenges with greater affordability

    Original URL path: https://www.rigol-uk.co.uk/aboutus.asp (2016-04-25)
    Open archived version from archive

  • Rigol Electronic Test & Measurement Equipment
    9786911 rigol telonic co uk View Larger Map Telonic Instruments Limited can be found at Toutley Industrial Estate Toutley Road Wokingham Berks RG41 1QN U K You can reach us by Telephone 44 0 118 9786911 Fax 44 0 118 9792338 E mail rigol telonic co uk About Us Company Info Contact Us My Account View Cart Sign In Order Status Products Product Index Category Index Helpful Info Shipping Returns

    Original URL path: http://www.rigol-uk.co.uk/Articles.asp?ID=260 (2016-04-25)
    Open archived version from archive



  •  


web-archive-uk.com, 2017-12-14